13
UK
[°C]
[K/min]
[%]
[kPa]
[m]
[h]
[1/h]
[kg]
[piece]
Environment
Applications
Class C to EN 60654-1 weatherproof application
Ambient temperature
-25...70, for service life ≤ 87600 h
10...40, for service life ≤ 175200 h
Rate of temperature change
0.5
Max. relative air humidity
5...95, briefly
5...70, permanently
Air pressure
80...106
Height above sea level
≤ 2000
Ionising radiation
not permissible
Salt spray
no
Protection
IP 65 / IP 67
Tests / approvals
EMC
IEC 60947-5-2
IEC 60947-5-3
EN 60947-5-2
EN 61000-4-2 ESD:
6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated:
20 V/m
EN 61000-4-4 Burst:
2 kV
EN 61000-4-6 HF conducted:
10 V
EN 61000-4-8:
30 A/m
EN 55011:
class B
Shock resistance
IEC 60947-5-2
Vibration resistance
IEC 60947-5-2
Safety classification
Mission time TM
≤ 175200, (20 years)
Safety-related reliability PF
H
D
1.0E-07
Mechanical data
Mounting
flush mountable
Housing materials
Brass white bronze coated; PBT
Weight
0.14
Displays / operating elements
Display
LED yellow (signal), LED green (power)
Electrical connection
Connection
M12 connector; Gold-plated contacts
Wiring
1: Safety-related logic unit
Accessories
Accessories (included)
2 lock nuts
Remarks
Remarks
Unless stated otherwise, all data refer to the 18x18x1 mm reference target plate to IEC
60947-5-2 (FE360 = mild steel) over the whole temperature range.
Pack quantity
1
Criteria: functional Safety (FS)