- 11 -
Montage
Safety instructions for wall installation:
• The changing table heater must be mounted on the wall in a stationary and level position. It must not be
mounted on the ceiling!
• The changing table heater must not be mounted on wood, plastic or other flammable materials or under plug
sockets.
•
IMPORTANT! Minimum distances:
The minimum distance between the heater and the changing table is 100
cm. A minimum distance of 35 cm between the heater and the ceiling must be observed at all times. The
heater must be placed at least 65 cm away from furniture and flammable materials. Fire hazard in case of
non-compliance!
• For installation in bathrooms or shower rooms, the regulations of the local utility company must be observed. The
heater must be positioned in such a manner that the pull switch cannot be reached from the bath or shower.
• Never install the unit above a bath tub!
1. Remove the assembly plate from the unit as shown in fig. 1.
2. Hold the wall bracket on the wall taking into account the minimum distances (fig. 5) and mark the drill holes with a
pencil. Use a spirit level to ensure the bracket is level.
3. Bolt the wall bracket to the wall (fig. 3) using the supplied screws and wall plugs.
4. Slide the changing table heater into the relevant grooves on the wall bracket (fig. 3).
5. Screw the changing table heater to the wall bracket (fig. 4) using the screws removed in fig. 1.
TIMER ON/OFF
35 cm
20 cm
100 cm
!
1
2
3
4
5
GB
English
Содержание FeelWell
Страница 2: ...2...
Страница 39: ...39 15 100 cm GR...
Страница 40: ...40 A B GR 230 V 400 800 W 1 25 185 cm IEC601 2 21 1 2 2 3 4 TIMER ON OFF 1 3 4 2...
Страница 41: ...41 100 cm 35 cm 65 cm 1 1 2 5 3 3 4 3 5 4 1 TIMER ON OFF 35 cm 20 cm 100 cm 1 2 3 4 5 GR...
Страница 43: ...43 reer GmbH Muehlstr 41 71229 Leonberg Germany www reer de GR reer reer reer...