Reer ARGOLUX AS 1103 Скачать руководство пользователя страница 35

WARRANTY

For every newly produced ARGOLUX series AS system, in normal utilisation

conditions, the REER company provides a 12 (twelve) month warranty

against material and manufacturing defects.
Over said time period, REER undertakes to eliminate any product faults

through repair or replacement of defective parts, totally free of charge,

where both materials and labour are concerned.
REER reserves the right to replace, in lieu of repairing, the defective system

in its entirety with another of the same type and characteristics.
This warranty is valid under the following  conditions:

The fault is notified to REER within twelve months of the date of

delivery of the product. 

The equipment and its components are in the conditions in which

they have been delivered by REER. 

Part numbers are clearly legible. 

The fault or malfunctioning has not been generated, directly or

indirectly, by:

Use for inappropriate purposes;

Failure to comply with utilisation instructions;

Negligence, erroneous use, incorrect maintenance;

Repairs, changes, adaptations not performed by REER person-

nel, tampering, etc.;

Accidents or collisions (also due to transport or force majeure

events);

Other causes which cannot be ascribed to REER.

Repairs shall be performed at the REER laboratories, where the material

must be delivered or shipped: transport expenses and possible risks of the

material being lost or damaged during transport shall be borne by the

customer.
All products and components replaced shall become the property of REER.
REER does not recognise any other warranties or rights other than those

expressly described above; in no case shall REER be liable for damages,

disruption of activities or other factors or circumstances in any way

correlated with the malfunctioning of its products or any parts thereof.

The main requisite to get a correct operating function of a photoelectric barrier is the

precise and full observance of all rules, directions and prohibitions shown in these

technical sheets.

REER s.p.a.

,

 consequently, declines all responsabilities for any complaint due

to the unrespect (even if partial) of such instructions.

Features might change without notice. No part of this sheet can be reproduced without permission of REER.

34

34

34

34

Содержание ARGOLUX AS 1103

Страница 1: ...12 INSTALLATION pag 15 15 15 15 POSITIONING AND SAFETY DISTANCES pag 17 17 17 17 GROUPING OF SEVERAL SETS pag 21 21 21 21 REFLECTING SURFACES pag 22 22 22 22 DEFLECTION MIRRORS pag 24 24 24 24 ELECTR...

Страница 2: ......

Страница 3: ...the receiver the control unit de energizes its output relays The result is the immediate stoppage of the dangerous movement if the control unit is correctly connected to the machine control circuitry...

Страница 4: ...olled and if its movement cannot be stopped at any time trolled and if its movement cannot be stopped at any time trolled and if its movement cannot be stopped at any time during the machine cycle dur...

Страница 5: ...thin the protection zone obscuring at least one beam figure least one beam figure least one beam figure least one beam figure 2 2 2 2 The resolution is always the same in the protection zone whatever...

Страница 6: ...3 Fig 3 Fig 3 Fig 3 Position and dimensions of the detection zone and the protection zone Position and dimensions of the detection zone and the protection zone Position and dimensions of the detection...

Страница 7: ...hall be used only to detect intrusion of the whole body of a person and not parts of the intrusion of the whole body of a person and not parts of the intrusion of the whole body of a person and not pa...

Страница 8: ...he correct operation of the both emitter and the receiver units thanks to its electrical connection with the receiver ASR The receiver provides the control unit with a signal through its unique relay...

Страница 9: ...red and compared During the 100 ms test period the outputs remain open contacts between terminals 8 13 and 9 12 remain open The test sequence can be generated at power up after any The test sequence c...

Страница 10: ...2 Yellow On Misalignment of the synchronisation beam BREAK 2 Yellow Alternately flickering Failure on the emitter unit BREAK 3 Red 4 Green On Protection field is clear output relay of AU S3 are energi...

Страница 11: ...0 000 Response time ms 13 14 15 16 17 Power supply Vdc 24 20 Power consump tion at 24Vdc Emitter W 4 2 Receiver 3 3 4 6 6 7 4 8 8 10 1 11 5 12 9 14 3 Operating temperature C 0 55 without condensation...

Страница 12: ...ing to EN 50022 35 Dimensions mm 100 x 73 x 120 Weight g 500 Refer to Load features in the Electrical connection chapter page 26 We recommend shielded cable where the level of electrical disturbances...

Страница 13: ...905 918 918 918 918 1103 1103 1103 1103 1105 1105 1105 1105 1118 1118 1118 1118 1203 1203 1203 1203 1205 1205 1205 1205 1218 1218 1218 1218 1403 1403 1403 1403 1405 1405 1405 1405 1418 1418 1418 1418...

Страница 14: ...LL and LH brackets LL and LH brackets Mounting pin and connectors Mounting pin and connectors Mounting pin and connectors Mounting pin and connectors Control unit AU S3 Control unit AU S3 Control unit...

Страница 15: ...lection mirrors Brackets for mirrors Brackets for mirrors Brackets for mirrors Brackets for mirrors Model Model Model Model H H H H SP 200S 370 SP 400S 540 SP 600S 715 SP 700S 885 SP 900S 1060 SP 1100...

Страница 16: ...orking cycle of the machine or any dangerous movement must be set in motion using a specific command device such as a pushbutton Therefore the ARGOLUX AS safety barrier must be used as a protective th...

Страница 17: ...at The control unit AU S3 should be installed in an enclosure at least IP54 least IP54 least IP54 least IP54 Before installing the safety barrier the following conditions should be observed Ambient t...

Страница 18: ...additional safety light curtain Safety distances Safety distances Safety distances Safety distances The safety distance between the protection field and the danger zone figure 7 page 18 should be lar...

Страница 19: ...ing to the EN 999 norm the 35mm resolution is suitable According to the EN 999 norm the 35mm resolution is suitable for hand detection when the barrier is not used for the for hand detection when the...

Страница 20: ...m resolution Versions with a 55mm resolution Versions with a 55mm resolution Devices with a 55mm resolution are considered by the EN 999 Devices with a 55mm resolution are considered by the EN 999 Dev...

Страница 21: ...n safety distance S from the dangerzonetotheouterbeamdependsontheheightHofthecurtainabove the ground This safety distance S should be calculated using the following formula S 1600 t S 1600 t S 1600 t...

Страница 22: ...sing the following formula S 1600 t S 1600 t S 1600 t S 1600 t1 t t t t2 2 2 2 850 850 850 850 Horizontal mounting Horizontal mounting Horizontal mounting Horizontal mounting Due to the optical charac...

Страница 23: ...1 Fig 11 Fig 11 Correct assembly of two neighbouring sets Correct assembly of two neighbouring sets Correct assembly of two neighbouring sets Correct assembly of two neighbouring sets Side by side ass...

Страница 24: ...e continuously detected all over the detection field The red LED of the receiver unit should never switch off while the test rod is being moved in the central area of the detection field and near the...

Страница 25: ...use Mirrors should be installed in such a way that the minimum calculated safety distance S is achieved on each side of the perimeter see figure 14 Total lenght of the perimeter should be smaller or e...

Страница 26: ...output relays A and B with guided contacts Even if these relays are specified for higher coil voltages and load currents make sure that the load features comply with the indications of the following...

Страница 27: ...er supply or any electromagnetic field source Test command Test command Test command Test command Test is applied when connection between terminals 15 and 16 is made Normally open contact of an extern...

Страница 28: ...A Direct use of control unit relay outputs Connection diagram A Direct use of control unit relay outputs Connection diagram B Use of additional relays K1 and K2 Connection diagram B Use of additional...

Страница 29: ...D s which help adjust the optical alignment To achieve an optimum alignment the optical axis of the outer beams of both emitter and receiver must mix up Install the receiver and adjust the emitter as...

Страница 30: ...t Each time the machine is powered up it is necessary to test Each time the machine is powered up it is necessary to test the correct response of the safety curtain over the whole the correct response...

Страница 31: ...n The cleaning must be done with a soft clean and wet cloth In a dusty environment it is recommended tosprayanantistaticproductontrasparent front plates after cleaning Never use abrasive or corrosive...

Страница 32: ...nd restore the power supply If no improvement is observed check the following points check all the wiring check that the supply features meet the ARGOLUX AS system supply tolerance check the presence...

Страница 33: ...S 605 1201456 ASE 605 1401456 ASR 605 1501456 AS 705 1201452 ASE 705 1401452 ASR 705 1501452 AS 905 1201457 ASE 905 1401457 ASR 905 1501457 AS 1105 1201453 ASE 1105 1401453 ASR 1105 1501453 AS 1205 12...

Страница 34: ...SP 1100S AS 1103 AS 1105 AS 1118 1201803 SP 1200S AS 1203 AS 1205 AS 1218 1201810 SP 1400S AS 1403 AS 1405 AS 1418 1201804 SP 1600S AS 1603 AS 1605 1201813 Kit of 4 antivibration dampers SAV 1 for LL...

Страница 35: ...rs changes adaptations not performed by REER person nel tampering etc Accidents or collisions also due to transport or force majeure events Other causes which cannot be ascribed to REER Repairs shall...

Отзывы: