With reference to figure 17:
•
Introduce the test rod in the detection zone and move it from top
to bottom in the center of the detection zone first, then near the
emitter and the receiver.
•
The red LED of the receiver should be permanently lit during the
move of the test rod in the detection zone.
The ARGOLUX AS safety curtain does not require any specific maintenance
intervention. However, it is recommended to clean transparent front plates
to avoid excessive dust accumulation.
The cleaning must be done with a soft, clean and wet cloth. In a dusty
environment, it is recommended to spray an antistatic product on trasparent
front plates after cleaning.
Never use abrasive or corrosive products, solvents or alcohol or any other
product which would obscure the transparent front plates. Never use a
woollen cloth in order to avoid accumulation of electrostatic charges on
transparent front plates.
Fig. 17
Fig. 17
Fig. 17
Fig. 17
Functional test of the barrier.
Functional test of the barrier.
Functional test of the barrier.
Functional test of the barrier.
Test rod
Test rod
Test rod
Test rod
P/N
Dimension
Models 35mm 7170119 Ø35mm
Models 55mm 7170122 Ø55mm
30
30
30
30