8541468 • 15/12/2021 • Rev.0

 

MOSAIC M1S COM - MASTER MODULE 

E

n

g

li

s

h

 

 

Reference should be made to the handbooks and the relative product 
and/or application standards to ensure correct use of devices connected 
to the MOSAIC within the specific application. 

 

The  ambient  temperature  in  the  place  where  the  system  is  installed 
must be compatible with the operating temperature parameters stated 
on the product label and in the specifications. 

 

For all matters concerning safety, if necessary, contact your country's 
competent safety authorities or the competent trade association. 

 

 

This information is about the usage and parametrisation of MOSAIC.  
ReeR  takes  no  responsibility  for  the  solutions  adopted  by  customers 
concerning  the  circuits,  the  electrical  diagrams  and  the  chosen 
configuration parameters of their application. The implemented circuits 
and  electrical  diagrams  and  the  choice  of  the  system  configuration 
parameter  values,  including  those  of  MOSAIC,  are  fully  under  the 
responsibility of the user. 

 

 

OVERVIEW 

 

MOSAIC  is  a  modular  safety  controller.  It  consists  of  a  master  unit 
(MOSAIC  M1S  COM),  which  can  be  configured  using  the  MSD  graphic 
interface, and a number of expansion units connected to the MOSAIC M1S 
COM via the proprietary MSC bus. 

 
 

 

Содержание 8046967

Страница 1: ...8541468 15 12 2021 Rev 0 1 Guida Rapida d Installazione Quick Installation Guide MOSAIC M1S COM Modulo Master Controllore Modulare di Sicurezza MOSAIC M1S COM Master Module Modular Safety Controller...

Страница 2: ...I RJ45 7 RESTART_FBK 8 USCITE 8 OUT STATUS 8 OUT TEST 8 OSSD 9 CHECKLIST DOPO L INSTALLAZIONE 9 CARATTERISTICHE TECNICHE 10 MOSAIC M1S COM MASTER MODULE 11 IMPORTANT SAFETY INSTRUCTIONS 11 OVERVIEW 12...

Страница 3: ...il paragrafo Elenco delle Normative applicabili Effettuare una accurata analisi dei rischi per determinare il livello di sicurezza necessario alla vostra applicazione facendo riferimento a tutte le n...

Страница 4: ...ersi alle autorit preposte in materia di sicurezza del proprio paese o alla associazione industriale competente Questa informazione riguarda l utilizzo e la parametrizzazionedi MOSAIC ReeR non si assu...

Страница 5: ...ssare quindi i moduli alla barra ponendo attenzione a inserire la contattiera posta sul fondo del modulo sul rispettivo connettore Premere il modulo delicatamente fino a sentire lo scatto del bloccagg...

Страница 6: ...tart 2 Input secondo EN 61131 2 Output di segnalazione programmabile PNP attivo alto 9 OSSD3 Output Uscita statica di sicurezza 3 PNP attivo alto 10 OSSD4 Output Uscita statica di sicurezza 4 PNP atti...

Страница 7: ...type C per consentire il collegamento ad un Personal Computer sul quale risiede il SW di configurazione MSD MOSAIC Safety Designer MOSAIC CONFIGURATION MEMORY MCM MOSAIC master MOSAIC M1S COM ha la p...

Страница 8: ...losa e l intera area di lavoro interessata risultino ben visibili Non deve essere possibile raggiungere il comando dall interno dell area pericolosa USCITE OUT STATUS Il segnale OUT STATUS pin 7 8 11...

Страница 9: ...tivo ingresso di feedback 1 canale doppio e 2 singoli CHECKLIST DOPO L INSTALLAZIONE MOSAIC in grado di rilevare autonomamente i guasti che avvengono in ciascun modulo Tuttavia al fine di garantire il...

Страница 10: ...C Max lunghezza cavo 3m Connettori di rete n descrizione 2 RJ45 per bus di campo e o connessione da remoto Cavo cat 5 o superiore Caratteristiche connessione di rete Velocit 10 100 Mbit autenticazion...

Страница 11: ...heir parameters and the connections that are made as per the risk analysis Read the Applicable Standards section carefully Perform an in depth risk analysis to determine the appropriate safety level f...

Страница 12: ...ety authorities or the competent trade association This information is about the usage and parametrisation of MOSAIC ReeR takes no responsibility for the solutions adopted by customers concerning the...

Страница 13: ...t between them the connectors just mounted 3 Fasten the units to the rail arranging the contacts on the base of the unit on the respective connector Press the unit gently until you feel it snap into p...

Страница 14: ...131 2 Programmable signal output PNP active high 9 OSSD3 Output Solid State Safety Output 3 PNP active high 10 OSSD4 Output Solid State Safety Output 4 PNP active high 11 RESTART_FBK3 STATUS3 Input Ou...

Страница 15: ...type C connector for the connection to a PC that is hosting the configuration software MSD Safety MOSAIC Designer MOSAIC CONFIGURATION MEMORY MCM A backup memory called MCM optional can be installed...

Страница 16: ...rea and the entire work area concerned are clearly visible It must not be possible to reach the control from inside the danger area OUTPUTS OUT STATUS The OUT STATUS signal pin 7 8 11 12 is a programm...

Страница 17: ...puts per channel with their relative feedback input 1 dual channel and 2 single channels CHECKLIST AFTER INSTALLATION The MOSAIC system is able to detect the faults that occurs in each own module Anyw...

Страница 18: ...for fieldbus and or remote connection remote connection Cable cat 5 or higher Network connection Speed 10 100 Mbit RSA encrypted authentication and AES 128 bit encrypted communication TCP port 300 Ava...

Страница 19: ...8541468 15 12 2021 Rev 0 19 DICHIARAZIONE DI CONFORMIT DECLARATION OF CONFORMITY...

Страница 20: ...20 8541468 15 12 2021 Rev 0 All REER product manuals are available at URL https www reersafety com it en download manuals...

Отзывы: