The Quasar Pro charger has program options built in that allow you to custom design
the functions of the charger to your needs.
The Quasar Pro charger has three programmable operational modes: Charge mode,
Discharge mode, and Cycle mode. The Cycle mode is not normally seen in a charger
and is a useful tool in cycling up (breaking in) new cells and testing used packs to
keep a record of their condition.
RECOMMENDED
SETTINGS
CHARGE RA
CHARGE RA
CHARGE RA
CHARGE RA
CHARGE RATES
TES
TES
TES
TES
Under 500mAH
0.5 amp
500mAH - 1100mAH
1.0 amp
1200mAH – 1600mAH
3.0 amp
1700mAH – 4000mAH
4.0 amp
DISCHARGE RA
DISCHARGE RA
DISCHARGE RA
DISCHARGE RA
DISCHARGE RATES
TES
TES
TES
TES
Less than 500mAH
0.3A or less
500mAH
0.5A or less
1100mAH
0.8A or less
1200-1700mAH
15A or less
1800-3000mAH
20A or less
OVER PEAK VOL
OVER PEAK VOL
OVER PEAK VOL
OVER PEAK VOL
OVER PEAK VOLT
TT
TTAGE CUTTOFF
AGE CUTTOFF
AGE CUTTOFF
AGE CUTTOFF
AGE CUTTOFF
1100mAH or less
3mV
1200-2400mAH NiCD
10mV
3000mAH NiMH
5mV
Delay time after charging
2 min.
Delay time after discharging
30 min.
Discharge cutoff is preset to .9volt per
cell.
CHARGING MODE
CHARGING MODE
CHARGING MODE
CHARGING MODE
CHARGING MODE
programmable settings
Number of cells.
Charge rate (adjustable
from 0.10 amp to 6.5
amp).
Type of battery.
mAH rating.
Over peak voltage cutoff
protection (adjustable
3mV/cell to 20mV/cell,
15mV).
DISCHARGING MODE
DISCHARGING MODE
DISCHARGING MODE
DISCHARGING MODE
DISCHARGING MODE
programmable settings
Discharge rate (adjust-
able 0.10amp to
20.0amp). Maximum
discharge rates are: 4-6
cells = 20 amps, 7-8
cells = 15 amps.
CYCLE MODE
CYCLE MODE
CYCLE MODE
CYCLE MODE
CYCLE MODE
programmable settings
Number of cycles.
Delay time after charge.
Delay time after dis-
charge.
The first time you use the charger you must set the values for these setups. To help
you select the proper settings, see recommended settings at right. Once set, these
values become the default settings and will automatically recall them each time you
turn the charger on.
The default settings may be changed at any time by entering the program mode,
scrolling to the appropriate screen and using the up and down buttons to make the
changes. These new settings will automatically become the new default settings.
To start programming, hook up the charger to your power source according to
steps 1-2 earlier in these instructions. Screen will read
Push SETUP button. Screen will read
Use Up and Down buttons to select NiCD or NiMH battery.
3
CHARGING MODES
PROGRAMMING THE CHARGER
QUASAR PRO
VERSION 1.0
CHARGER MODE
XXXX XXXX XXXX
BATTERY TYPE IS
NiMH
1
2