Frequency Measurement
1...Set.the.function.switch.to.the.
Hz
.position.
2...Insert.the.black.test.lead.banana.plug.into.the.negative.(COM).jack.and.
the.red.test.lead.banana.plug.into.the.positive.
Hz
.jack.
3...Touch.the.test.probe.tips.to.the.circuit.under.test.
4..Read.the.frequency.in.the.display..The.digital.reading.will.indicate.the.
proper.decimal.point,.symbols.(kHz,.MHz).and.value.
Temperature Measurement
1..Set.the.function.switch.to.the.Type.K.
ºF
.or.
ºC
.position.
2..Insert.the.Temperature.Probe.into.the.input.jacks,.making.sure.to..
observe.the.correct.polarity.
3..Press.the.
MoDE
.button.until.“
ºF or ºC
”.appears.in.the.display.
4..Touch.the.Temperature.Probe.head.to.the.part.whose.temperature.you.
wish.to.measure..Keep.the.probe.touching.the.part.under.test.until.the.
reading.stabilizes.(about.30.seconds).
5..Read.the.temperature.in.the.display.
noTE:
The temperature probe is fitted with a type K mini connector.
.
A.mini.connector.to.banana.connector.adaptor.is.supplied.for..
connection.to.the.input.banana.jacks.
Specifications
Technical
insulation:
.
Class2,.Double.insulation
overvoltage category:
.
CATIV.600V,CATIII.1000V.
noTE:
.These.meters.meet.CAT.III.and.CAT.IV.IEC.61010.standards...
The IEC 61010 safety standard defines four overvoltage
.
categories.(CAT.I.to.IV).based.on.the.magnitude.of.danger.from.
transient.impulses..CAT.III.meters.are.designed.to.protect.against.
transients in fixed-equipment installations at the distribution level;
CAT.IV.meters.are.designed.to.protect.against.transients.from.the.
primary.supply.level.(overhead.or.underground.utility.service).