7. Recommended Illumination:

Locations 

Lux

*Office
 Conference, Reception room 

200 ~ 750

 Clerical work 

700 ~ 1,500

 Typing drafting 

1000 ~ 2,000

*Factory
 Packing work, Entrance passage 

150 ~ 300

 Visual work at production line 

300 ~ 750

 Inspection work 

750 ~ 1,500

 Electronic parts assembly line 

1500 ~ 3,000

*Hotel
 Public room, Cloakroom 

100 ~ 200

 Reception, Cashier 

200 ~ 1,000

*Store
 Indoors Stairs Corridor 

150 ~ 200

 Show window, Packing table 

750 ~ 1,500

 Forefront of show window 

1500 ~ 3,000

*Hospital
 Sickroom, Warehouse 

100 ~ 200

 Medical Examination room 

300 ~ 750

 Operating room
 Emergency Treatment 

750 ~ 1,500

*School
 Auditorium, Indoor Gymnasium 

100 ~ 300

 Class room 

200 ~ 750

 Laboratory Library Drafting room  

500 ~ 1,500

Battery Replacement

If the sign “BAT” appears on the LCD display, it indicates that the battery 
should be replaced. Open the  battery case and replace the expired 

.

battery with new battery. (1 x 12V battery, A23 or equivalent) 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание ST-1301

Страница 1: ...reedinstruments www com Pantone 485 123 485 0 100 100 10 123 0 18 100 0 Model ST 1301 Light Meter Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...t size and light weight 3 1 2 digital LCD display with LUX Fc LOBAT MAX HOLD indication Accurately displays light level in terms of Foot Candles Fc or Lux over wide range Measures from 0 to 50000 Lux...

Страница 3: ...pprox 15 minutes of inactivity Power One standard 12V A23 battery Dimensions Wt 188 H x 64 5 W x 24 5 D mm 160g Photo Detector Dimensions Wt 115 X 60 X 27 mm 80g Light Measuring Range 200 2000 20000 5...

Страница 4: ...LD If you press the MAX button the maximum reading will be held Pressing the button once again will release the hold and allow a further measurement 5 DATA HOLD The reading will be held when the Data...

Страница 5: ...nd a higher range should be selected 5 When the measurement is completed replace the photo detector from the light source 6 Spectral sensitivity characteristic To the detector the applied photo diode...

Страница 6: ...r 150 200 Show window Packing table 750 1 500 Forefront of show window 1500 3 000 Hospital Sickroom Warehouse 100 200 Medical Examination room 300 750 Operating room Emergency Treatment 750 1 500 Scho...

Страница 7: ...____________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________...

Отзывы: