Specifications

Circuit:.

Custom.microprocessor.LSI.circuit

Display:.

52mm.x.38mm.LCD.with.backlight

Air.velocity.units:.

m/S,.Km/h,.FPM,.Knots,.Mph

Temperature.units:.

(°C,.°F)

Auto.Sampling.Time:.

1,.2,.5,.10,.30,.60,.120,.300,.600,.1800,..
3600.seconds

Memory.Card:.

SD.memory.card,.1.GB.to.16.GB

Sampling.Time.of.Display:. Approx..1.second
Data.Output:.

USB/RS232.PC.computer.interface

Temperature.Range:.

0-50°C.(0-122°F)

Resolution:.

0.1°C/0.1°F

Accuracy:.

±.0.8°C/1.5°F

Operating.Temperature:.

0-50°C.(0-122°F)

Operating.Humidity:.

Less.than.85%.R.H..

Power.Supply:.

UM3/AA.(1.5.V).x.6.batteries.

Weight:..

515g/1.13lb

Dimensions:.

Main.instrument.:203.x.76.x.38mm.
Anemometer.Sensor.Head:.72mm.Dia..

Includes:.

Anemometer.probe.and.a.hard.carrying.case

Optional.accessories:.

2G.SD.Card.(SD-2GB)..
Type.K.thermocouple.probe.(TP-01).
USB.cable.(USB-01).
RS232.cable.(UPCB-01).
Data.Acquisition.Software.(SW-U801-WIN)

Visit.us.at.www.reedinstruments.com.for.more.information.on.our.Optional.
Accessories,[email protected]

continued...

www.netzerotools.com

www.netzerotools.com

Содержание SD-4207

Страница 1: ...Black Model Instruction Manual Anemometer Thermometer Datalogger SD 4207 SD 4214 www netzerotools com www netzerotools com...

Страница 2: ...velocity unit 7 Type K J Thermometer measurement 8 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the Time 10 Check Sampl...

Страница 3: ...sensor for fast response time Real time SD memory card datalogger with a built in clock and calendar Sampling time set from 1 second to 3600 seconds Meter can switch to a Manual Datalogging No extra...

Страница 4: ...o 16 GB Sampling Time of Display Approx 1 second Data Output USB RS232 PC computer interface Temperature Range 0 50 C 0 122 F Resolution 0 1 C 0 1 F Accuracy 0 8 C 1 5 F Operating Temperature 0 50 C 0...

Страница 5: ...126 0Km h 0 1Km h 2 0 8 Km h Mph 0 9 78 3mph 0 1mph 2 0 4 mph Knots 0 8 68 0 knots 0 1 Knots 2 0 4 Knots FPM 79 6890 FPM 1 FPM 2 40 FPM Type K J thermometer Sensor Type Resolution Range Accuracy Type...

Страница 6: ...ment Description 1 Display 2 Power ESC Backlight Button 3 Hold Function Next Button 4 REC Enter Unit Button 5 SET Down Time Check Button 6 Logger Up Sampling Time Check Button 7 Probe input socket 8 T...

Страница 7: ...ter measurement Release the Function Button to choose the displayed function Air velocity Temperature measurement 1 When the meter is off plug the Air Velocity Probe Plug into the Probe Input Socket t...

Страница 8: ...ured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data record function records the m...

Страница 9: ...ed to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded to the SD card is defaulted used...

Страница 10: ...time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Position Number press the Down Button and the lower position nu...

Страница 11: ...S files When that number has been reached the meter will then will generate a new folder with a subsequent number for example AMA02 Max number of AMA folders is 10 Data Transfer from SD card to Comput...

Страница 12: ...et beeper sound ON OFF tYPE Select the Thermometer to Type K or Type J t CF Select the temperature unit to C or F SP t Set sampling time Hour Minute Second Sd F SD memory card Format While in the Adva...

Страница 13: ...shows PoFF use the Up or Down But tons to select the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to save the setting as the default...

Страница 14: ...ess the Esc Button Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 2 After the Sampling...

Страница 15: ...m which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W...

Страница 16: ...set Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 Wh...

Страница 17: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Страница 18: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Страница 19: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Страница 20: ..._____________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________________...

Отзывы: