INSTRUMENTS

cally. While taking measurements, press the Backlight Button and the LCD 
Backlight will turn off. Press the Backlight Button once again to turn the 
LCD Backlight back ON.

Datalogger

Preparation Before Executing the Datalogger Function: 

1.  Insert the optional SD card into the SD card socket. 
2.  Before you use an SD card with this meter for the first time, it is 

recommend to format the SD card. See Advanced Settings sec-
tion of this manual for instructions.

3.  If this is the first time the meter is used you need to adjust the 

clock. See Advanced Settings section of this manual for instruc-
tions.

4.  Now you need to set the decimal format. The numerical data 

structure downloaded to the SD card is defaulted used the “ . 
“ as the decimal, for example “20.6” “1000.53” . But in certain 
countries the “ , “ is used as the decimal point, for example “ 20, 
6 “ “1000,53”. See Advanced Settings section of this manual for 
instructions on how to change the Decimal Character. 

Auto Datalogger (Set sampling time ≥1 second) 

1.  Start Datalogging; press the REC Button, and the “REC” symbol 

will appear on the LCD screen, then press the Logger Button, the 
“REC” symbol will flash while the measuring data and time infor-
mation is being saved in memory. To set the sampling time, and to 
toggle the beeper sound on or off, refer to the Advanced Settings 
section of this manual.

2.  Pause the Datalogging; while Datalogging, if press the Logger 

Button once. While paused, the “REC” symbol will stop flashing. 
Press the Logger Button again to resume Datalogging, and the 
“REC” symbol will begin to flash again. 

3.  Stop Datalogging; while the Datalogger function is paused, press 

the REC Button for 2 seconds. The “REC” symbol will disappear 
indicating the Datalogging function has stopped. 

continued ...

Содержание SD-230

Страница 1: ...Model pH ORP Meter Datalogger SD 230 reedinstruments www com Instruction Manual Rich Black 20 20 20 100 Only if you REALLY need them...

Страница 2: ...Required Equipment for Calibration 7 Calibration Procedure 7 8 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the Time 10...

Страница 3: ...can switch to a Manual Datalogging No extra software needed just plug the SD card into the computer and it downloads directly to EXCEL SD card capacity 1 GB to 16 GB Easy to read LCD with backlight A...

Страница 4: ...puter interface Operating Temperature 0 50 C 0 122 F Operating Humidity Less than 85 R H Power Supply UM3 AA 1 5 V x 6 batteries Weight 489g 1 08lb Dimensions 177 x 68 x 45mm 7 0 x 2 7 x 1 9 Optional...

Страница 5: ...you REALLY need them Operating Instructions 1 Display 2 Power Backlight Button 3 Hold ESC Button 4 REC Enter Button 5 Up Button 6 Down Function Button 7 Time Button 8 Logger Set Sampling Time Check B...

Страница 6: ...Manual Temperature Compensation value Refer to the Advanced Settings section for instructions 4 Hold the Electrode Handle and let the Sensing head get fully im mersed the measured solution Shake the p...

Страница 7: ...ssary Calibra tion also ensures accurate measurements Required Equipment for Calibration 1 Optional pH Electrode 2 Optional pH Buffer Solutions Calibration Procedure 1 Connect the Optional pH Electrod...

Страница 8: ...n once and the mea sured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data record fu...

Страница 9: ...rical data structure downloaded to the SD card is defaulted used the as the decimal for example 20 6 1000 53 But in certain countries the is used as the decimal point for example 20 6 1000 53 See Adva...

Страница 10: ...press the Down Button and the lower position number will flash on the display Press the Up or Down Buttons to set the Position Number 1 to 99 to help identify the measurement location The lower Displ...

Страница 11: ...f PHA folders is 10 Data Transfer from SD card to Computer EXCEL Software 1 After Datalogging remove the SD card from the SD card slot 2 Plug in the SD card into the Computer s SD card slot or insert...

Страница 12: ...the Advanced Setting function press the Esc Button to exit and to return to normal functioning SD memory card Format Please Note Formatting the SD card erases all data from that SD card 1 When the lo...

Страница 13: ...ve the setting as the default To exit Advanced Set tings press the Esc Button Auto power OFF management 1 When the lower display shows PoFF use the Up or Down But tons to select the value yES Enable A...

Страница 14: ...ecting C or F press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button Set pH Manual Temperature Compensation value 1 When the lower display shows t SEt...

Страница 15: ...Meter 3 5mm Jack Plug PC 9W D Connector Center Pin Pin 2 Ground Shield Pin 5 The 16 digit data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 D0...

Страница 16: ...r more information Battery Replacement 1 When the left corner of LCD display shows it is necessary to replace the battery 2 Loosen the screws of the Battery Cover and remove 3 Remove the batteries and...

Страница 17: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Страница 18: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Страница 19: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Страница 20: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Отзывы: