INSTRUMENTS

Features

•  Simultaneously monitors carbon dioxide (CO

2

), relative humidity and 

temperature

•  Instantaneous readings are displayed on a high resolution LCD with 

backlight

•  Dew point and wet bulb temperatures can also be displayed
•  Displays STEL readings (Short-Term Exposure Limit) over a 15-minute 

period and TWA readings (Time-Weighted Average) over a period of 8 

hours

•  Hold function freezes displayed reading
•  Maximum, minimum and average functions
•  Low drift, non-dispersive infrared CO

2

 sensor

•  Audible warning alarm of excessive CO

2

 concentrations

•  RS232 output

Specifications

Ranges: 

CO

2

: 0 to 5,000 ppm;

 

Temperature: -10 to 60°C (14 to 140°F);

 

 

Humidity: 

0 to 99.9% RH;

 

 

Dew Point: -73.4 to 60°C; 

 

 

Wet Bulb: 

-13.3 to 60°C

Resolution: 

CO

2

: 1 ppm; Temperature: 0.1°C/°F; 

 

Humidity: 0.1% RH 

Accuracy: 

CO

2

: ±5% rdg. ±50 ppm; 

 

Temperature: ±0.6°C (±0.9°F); 

 

 

Humidity: ±3% RH @ 25°C (10 to 90% RH) 

 

 

±5% RH <10% & >90%

Sensors: 

CO

2

: Non-Dispersive Infrared (NDIR); 

 

Humidity: Rotronic capacitor

Response Time: 

30 seconds

Audible Alarm: 

80dB

continued...

www.

.com

[email protected]

1.800.561.8187

Содержание R9900

Страница 1: ...reedinstruments www com Model Instruction Manual Indoor Air Quality Meter R9900 Rich Black 20 20 20 100 Only if you REALLY need them www com information itm com 1 800 561 8187...

Страница 2: ...w 0 27 100 0 Blue 100 80 30 5 Only if you REALLY need them Table of Contents Features 3 Specifications 3 4 Instrument Description 4 5 Operating Instructions 5 8 Data Hold 5 Backlight 5 Max Min Weighte...

Страница 3: ...minute period and TWA readings Time Weighted Average over a period of 8 hours Hold function freezes displayed reading Maximum minimum and average functions Low drift non dispersive infrared CO2 senso...

Страница 4: ...ne batteries Battery Life 24 hours Includes 4 AA batteries and a hard carrying case Optional accessories 33 Calibration Salt RHA 33 75 calibration salt RHA 75 Instrument Description Power Set button C...

Страница 5: ...powering on the meter will beep and commence a 30 second warm up The meter will then enter the normal measuring mode displaying the current CO2 temperature and humidity readings Readings will be updat...

Страница 6: ...l continue to measure normally NOTE If the meter is turned on for less than 15 minutes the STEL value will be the weighted average of readings taken since power on This is the same for TWA values befo...

Страница 7: ...utton and modify the tempera ture unit by pressing the UP or DOWN buttons Press the ENTER button to save the setting or press the ESC button to cancel CO2 Calibration This meter is calibrated at a sta...

Страница 8: ...the calibrating value of 33 32 7 if at 25 C will blink on the LCD along with the current temperature at the left The meter is now calibrating and will finish when CAL and humidity stop blinking which...

Страница 9: ...ssary Fixed readings Check if the data hold function is activated Slow response Check to see if the airflow channels on the rear are blocked Error messages E01 CO2 sensor damaged E02 The value is unde...

Страница 10: ...n the battery compartment on the rear and make sure they are correct polarity and in good contact Notes __________________________________________ ________________________________________________ ____...

Отзывы: