background image

reedinstruments

www

com

2

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Table of Contents

Features ......................................................................................... 3

Specifications .............................................................................3-4

Operating Instructions ................................................................5-6

Current Source ........................................................................... 5

Current Measurement ................................................................. 5

Two-Wire Loop Power and Current Measurement ....................... 6

DC mV Source ............................................................................ 6

Battery Replacement ..................................................................... 6

 
 
 
 
 
 
 
 

For service on this or any other REED product or information on other 
REED products, contact REED Instruments at [email protected]

www.reedinstruments.com

1-877-849-2127 | [email protected]

 

Содержание R8800

Страница 1: ...com Model R8800 Voltage Current Calibrator Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 www reedinstruments com 1 877 849 2127 info r...

Страница 2: ...m Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Table of Contents Features 3 Specifications 3 4 Operating Instructions 5 6 Current Source 5 Current Measurement 5 Two Wire Loop Power and Cu...

Страница 3: ...dheld calibrator Able to power or measure a two wire current loop Provides a precise current and DC mV source Calibrates and measures process signals Measures Current signals Adjustable 0 24mA current...

Страница 4: ...nt for loads up to 500 ohms Output 20mA current for loads up to 400 ohms FS Full Scale Current Measurement FS Full Scale Two Wire Loop Power and Current Measurement Provides power DC 12V 2V to the loo...

Страница 5: ...press the 0 24mA button for a 0 1mA display resolution 4 Adjust the CAL ADJUST knob to match the current output display value Current Measurement 1 Insert the black test lead banana plug into the nega...

Страница 6: ...it that is going to be measured and connect the red test probe and the black test probe securely in series with the load in which the current is to be measured DC mV Source 1 Insert the black test lea...

Страница 7: ...m Mod le Calibrateur de courant tension Manuel d utilisation Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 R8800 www reedinstruments com 1 877 849 2127 in...

Страница 8: ...80 30 5 Pantone 485 Red 10 100 100 5 Table des Mati res Caract ristiques 3 Sp cifications 3 4 Mode d emploi 5 6 Source de courant 5 Mesure de courant 5 Alimentation avec boucle deux fils et mesure de...

Страница 9: ...er ou de mesurer une boucle de courant deux fils Pourvoit un courant pr cis et une source de tension mV en courant continu talonne et mesure les signaux de processus Mesure les signaux de courant Sour...

Страница 10: ...urant de sortie 20 mA pour des charges jusqu 400 ohms p e de la pleine chelle Mesure de courant p e de la pleine chelle Alimentation avec boucle deux fils et mesure de courant Pourvoit une alimentatio...

Страница 11: ...solution d affichage de 0 1 mA 4 Ajustez le bouton CAL ADJUST pour correspondre la valeur d affichage du courant de sortie Mesure de courant 1 Ins rez la fiche banane du fil d essai noir dans la pris...

Страница 12: ...t la sonde d essai noire de fa on s curitaire en s rie avec la charge dans laquelle on d sire mesurer le courant Source de tension mV en courant continu 1 Ins rez la fiche banane du fil d essai noir d...

Отзывы: