Product Quality

This product has been manufactured in an ISO9001 facility and has been 
calibrated during the manufacturing process to meet stated product 
specifications. If a certificate of calibration is required please contact the 
nearest authorized REED distributor or authorized Service Center. Please 
note an additional fee for this service will apply.

Safety

Never attempt to repair or modify your instrument. Dismantling your 
product, other than for the purpose of replacing batteries, may cause 
damage that will not be covered under the manufacturer's warranty. 
Servicing should only be provided by an authorized service center.

Features

•  High accuracy of ±1.4 dB meets Type 2 standards
•  Triple range measurement (60dB dynamic range)
•  A & C frequency weighting
•  Fast & Slow time weighting
•  Large, easy-to-read LCD display
•  Digital analog bargraph
•  Data hold and Min/Max hold
•  AC/DC output signal for use with dataloggers
•  Tripod mount for long-term monitoring
•  Low battery indicator and auto shut off

Included

•  Windshield Ball
•  Hard Carrying Case
•  Battery

www.

.com

[email protected]

1.800.561.8187

Содержание R8060

Страница 1: ...Sound Level Meter Instruction Manual R8060 www com information itm com 1 800 561 8187...

Страница 2: ...C DC Signal Output Jack 8 Applications 9 Accessories and Replacement Parts 9 Product Care 9 Product Warranty 10 Product Disposal and Recycling 10 Product Support 10 Introduction Thank you for purchasi...

Страница 3: ...ther than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features...

Страница 4: ...enser Digital Analog Bargraph Yes 30 segment Display 4 digit LCD Min Yes Max Yes Alarm Indicators Under and Over visual on screen Auto Shut off Yes after 30 mins off Tripod Mountable Yes Low Battery I...

Страница 5: ...0 AC DC Output Terminal 11 Tripod Mounting Screw 12 Battery Cover Display Description Bar Graph Indicator Reading Indicator Battery Capacity Indicator C Weighting Indicator Auto Power Off Indicator Un...

Страница 6: ...upper limit of the selected dB range has been exceeded Adjust the selected dB range until the over range indicator disappears from the screen Further more if the under range indicator appears during y...

Страница 7: ...been exposed to extreme conditions or has not been used in a long period of time the meter should be calibrated by following steps 1 through 6 below 1 Remove windshield ball 2 While the meter is off p...

Страница 8: ...external systems For example the AC output can be used with a frequency analyzer or oscilloscope to identify the frequency level during a measurement The DC output is used to identify the dB level du...

Страница 9: ...your part listed here For a complete list of all accessories and replacement parts visit your product page on www reedinstruments com Product Care To keep your instrument in good working order we rec...

Страница 10: ...at 1 877 849 2127 or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and...

Страница 11: ...Test Measure with Confidence Check out our latest Products www com information itm com 1 800 561 8187...

Страница 12: ...AIR VELOCITY TEMPERATURE HUMIDITY SOUND MOISTURE ELECTRICAL www com information itm com 1 800 561 8187...

Отзывы: