REED R5050 Скачать руководство пользователя страница 7

reedinstruments

www

com

7

INSTRUMENTS

INSTRUMENTS

Instrument Description

1.  Current Sensing Clamp
2.  Clamp opening handle
3.  Function select dial
4.  Hold Button
5.  Peak Hold Button
6.  Maximum Minimum Button
7.  AC/DC Select Button 
8.  Relative Button
9.  LCD Display
10. "COM" Terminal
11. " + " Test Terminal

Display Description

Auto Power Off indication

Low battery indication

Direct Source indication

Alternative

Positive Peak detect indication

Relative indication

Negative Peak detect indication

Manual range indication

Data Hold indication

Diode function indication

Continuity with beeper

Polarity indication 

Analog Bar display

Resistance 
measurement indication

Voltage & Current 
measurement  
indication

Frequency 
measurement indication

continued ...

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R5050

Страница 1: ...reedinstruments www com R5050 TRMS AC DC Clamp Meter Instruction Manual Model INSTR INSTR www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...nction 8 MAX MIN Function 8 REL Function 8 Measurement Procedures 9 12 Current Measurement 9 ACA 9 DCA 9 Voltage measurement 10 Resistance measurement 10 Continuity Test 11 Diode Test 11 Frequency mea...

Страница 3: ...inuity tests on a live circuit Exercise extreme caution when measuring live systems with voltages greater than 60VCC or 30VCA Use extreme care when working around bus bars and bare conductors Do not u...

Страница 4: ...ccording symbols and range input signal Polarity is displayed when negative signal applied to the input Over Load is displayed when input signal exceeds range Sample Rate 2 times sec for digital data...

Страница 5: ...ified from 5 to 100 of the range For the accuracy add 1 of reading on Crest Factor 1 4 CF 3 at full scale CF 6 at half scale ACA Range Resolution Accuracy Overload Protection 40A 0 01A 50 60Hz 1 9 rdg...

Страница 6: ...4000 1 Diode Range Test Current Open Circuit Voltage Overload Protection 1 7mA Max 6V Max 600Vrms Continuity Range Active Region Overload Protection 100 600Vrms Frequency Hz Autorange Function Range...

Страница 7: ...o Power Off indication Low battery indication Direct Source indication Alternative Positive Peak detect indication Relative indication Negative Peak detect indication Manual range indication Data Hold...

Страница 8: ...the PEAK HOLD buttons to keep the peak reading To return the meter back to normal operation press the PEAK button for 2 seconds When the function range changes the meter will require another calibrati...

Страница 9: ...n selector to proper current range ACA Open the clamp by pressing the jaw opening handle and insert the cable to be measured into the jaw Choose AC current measurement by pressing the AC DC button for...

Страница 10: ...he LCD panel Resistance measurement Switch the main function to the range verify that the power line is disconnected from the system Connect the Red test lead to the terminal and the Black one to the...

Страница 11: ...n to the range verify that the power line is disconnected from the system Connect the Red test lead to terminal and the Black one to the COM terminal Connect the tips of the Red test lead to the anode...

Страница 12: ...ne the LCD panel Frequency measurement with the clamp Switch the main function to the Hz range Open the clamp by pressing the clamp opening handle and insert the cable to be measured into the clamp Cl...

Страница 13: ...tened To avoid contamination or static damage do not touch the circuit board without proper static protection Notes If the meter is not going to be used for a long time take out the battery and do not...

Отзывы: