REED R5050 Скачать руководство пользователя страница 3

reedinstruments

www

com

3

INSTRUMENTS

INSTRUMENTS

 Safety

•  Read this manual before using the meter and follow all safety guidelines.
•  Use the meter only as specified in this instruction manual. Otherwise 

the meters protection may be impaired. 

•  Never use this meter on a circuit with voltages greater than 750Vrms @ 50/60 Hz. 
•  Do not operate the meter if the body or test leads look damaged.
•  Check the function selector range switch and make sure it is at the 

correct position before each measurement is taken.

•  Do not perform resistance and continuity tests on a live circuit.
•  Exercise extreme caution when measuring live systems with voltages 

greater than 60VCC or 30VCA.

•  Use extreme care when working around bus bars and bare conductors. 
•  Do not use the meter in over range/overload conditions (OL).
•  Change the battery when the 

 symbol appears to avoid incorrect readings.

Environmental Conditions

Altitude up to 2000 meters.
Operating Temperature: 0°C to 40°C, <80% RH, non-condensing
Storage Temperature: -10°C to 60°C, <70% RH, battery removed
Pollution Degree: 2

Symbols

Attention! Refer to operation instructions.

Dangerous voltage may be present at terminals.

This instrument has double insulation.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R5050

Страница 1: ...reedinstruments www com R5050 TRMS AC DC Clamp Meter Instruction Manual Model INSTR INSTR www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...nction 8 MAX MIN Function 8 REL Function 8 Measurement Procedures 9 12 Current Measurement 9 ACA 9 DCA 9 Voltage measurement 10 Resistance measurement 10 Continuity Test 11 Diode Test 11 Frequency mea...

Страница 3: ...inuity tests on a live circuit Exercise extreme caution when measuring live systems with voltages greater than 60VCC or 30VCA Use extreme care when working around bus bars and bare conductors Do not u...

Страница 4: ...ccording symbols and range input signal Polarity is displayed when negative signal applied to the input Over Load is displayed when input signal exceeds range Sample Rate 2 times sec for digital data...

Страница 5: ...ified from 5 to 100 of the range For the accuracy add 1 of reading on Crest Factor 1 4 CF 3 at full scale CF 6 at half scale ACA Range Resolution Accuracy Overload Protection 40A 0 01A 50 60Hz 1 9 rdg...

Страница 6: ...4000 1 Diode Range Test Current Open Circuit Voltage Overload Protection 1 7mA Max 6V Max 600Vrms Continuity Range Active Region Overload Protection 100 600Vrms Frequency Hz Autorange Function Range...

Страница 7: ...o Power Off indication Low battery indication Direct Source indication Alternative Positive Peak detect indication Relative indication Negative Peak detect indication Manual range indication Data Hold...

Страница 8: ...the PEAK HOLD buttons to keep the peak reading To return the meter back to normal operation press the PEAK button for 2 seconds When the function range changes the meter will require another calibrati...

Страница 9: ...n selector to proper current range ACA Open the clamp by pressing the jaw opening handle and insert the cable to be measured into the jaw Choose AC current measurement by pressing the AC DC button for...

Страница 10: ...he LCD panel Resistance measurement Switch the main function to the range verify that the power line is disconnected from the system Connect the Red test lead to the terminal and the Black one to the...

Страница 11: ...n to the range verify that the power line is disconnected from the system Connect the Red test lead to terminal and the Black one to the COM terminal Connect the tips of the Red test lead to the anode...

Страница 12: ...ne the LCD panel Frequency measurement with the clamp Switch the main function to the Hz range Open the clamp by pressing the clamp opening handle and insert the cable to be measured into the clamp Cl...

Страница 13: ...tened To avoid contamination or static damage do not touch the circuit board without proper static protection Notes If the meter is not going to be used for a long time take out the battery and do not...

Отзывы: