Instrument Description

1.  Display 
2.  Power Button
3.  Hold Button
4.  REC Button
5.  Unit/Zero Button
6.  AC/DC Button 
7.  Input Socket
8.  Probe Handle

9.  Probe Sensor
10. Probe Plug
11. USB/RS232 Output
12. Reset Button
13. AC/DC 9V Power Adapter Input Socket
14. Stand
15. Battery Compartment/Cover

www.

.com

[email protected]

1.800.561.8187

Содержание GU-3001

Страница 1: ... 20 20 20 100 Only if you REALLY need them Rich Black 20 20 20 100 Only if you REALLY need them Model Milligauss Meter GU 3001 reedinstruments www com Instruction Manual www com information itm com 1 800 561 8187 ...

Страница 2: ... 100 0 Blue 100 80 30 5 Only if you REALLY need them Table of Contents Features 3 Specifications 4 Instrument Description 5 Operating Instructions 6 8 DC Magnetic Field Measurement 6 AC Magnetic Field Measurement 7 Data Hold 7 Data Record Max Min reading 7 Auto Power Off Managment 8 System Reset 8 Battery Replacement 8 PC Serial Interface 9 www com information itm com 1 800 561 8187 ...

Страница 3: ...measure the absolute environment Earth s magnetic field as reference Zero adjustment button for relative measurement Heavy duty compact housing with hard carrying case designed for easy carry out operation Easy to read LCD with backlight Auto power off or manual power off Data hold record max and min reading High accuracy microcomputer circuit Power by UM3 AA 1 5 V x 6 batteries USB RS232 Computer...

Страница 4: ...Accuracy 2 2mG Frequency Response AC DC 40 Hz to 10 KHz Field Direction Uniaxail Sampling Time Approx 1 second Data Output RS 232 USB PC computer interface Operating Temperature 0 50 C 0 122 F Operating Humidity Less than 85 R H Power Supply UM3 AA 1 5 V x 6 batteries Weight Meter 350g 0 lb Probe 78g 0 17lb Dimensions Meter 173 x 68 x 42mm Probe 177 x 29 x 17mm Includes Probe and hard carrying cas...

Страница 5: ...0 27 100 0 Blue 100 80 30 5 Only if you REALLY need them Instrument Description 1 Display 2 Power Button 3 Hold Button 4 REC Button 5 Unit Zero Button 6 AC DC Button 7 Input Socket 8 Probe Handle 9 Probe Sensor 10 Probe Plug 11 USB RS232 Output 12 Reset Button 13 AC DC 9V Power Adapter Input Socket 14 Stand 15 Battery Compartment Cover www com information itm com 1 800 561 8187 ...

Страница 6: ... due to the present natural magnetic field Be sure to follow the Zero Ad justment procedures described in the DC Magnetic Field procedures DC Magnetic Field Measurement As the device has extremely high sensitivity the LCD display will vary greatly even a slight movement the probe It is recommended to firmly fix the probe before measurement 1 Turn on the meter by pressing the Power Button To turn t...

Страница 7: ... appear on the display With the REC symbol on the display 1 Press the REC Button once and a REC MAX symbol along with the maximum value will appear on the display To delete the maximum value press the Hold Button once and the display will show a REC symbol only and execute the memory function continuously 2 Press the REC Button again and a REC MIN symbol along with the minimum value will appear on...

Страница 8: ...tting or press the Hold Button to exit without saving System Reset If an error occurs press the Reset Button with a Pin If the Reset Button does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 When the left corner of LCD display shows it is necessary to replace the battery 2 Loosen the screws of ...

Страница 9: ...he user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W D Connector Center Pin Pin 2 Ground Shield Pin 5 The 16 digit data stream will be displayed in the following format D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 D0 End Word D1 to D4 Upper Display reading D1 LSD D4 MSB D...

Страница 10: ..._ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ______...

Страница 11: ..._ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ______...

Страница 12: ..._ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ______...

Отзывы: