background image

8

www.REEDINSTRUMENTS.com

Auto Power Off

1.  To preserve battery life, the meter is programmed to turn itself off 

after 30 minutes of inactivity.

2.  To turn this function off, press and hold the 

HOLD

 button while 

powering on the meter. 

3.  Release both buttons simultaneously.
4.  The Auto Power Off indicator will not appear on the display at start 

up, confirming this feature is now disabled.

5.  If the meter is turned off then back on, the "Auto Power Off" feature 

will be enabled again.

Backlight

Press the Backlight Button to turn the LCD Backlight on and off. The 
backlight will automatically turn off after 30 seconds in order to preserve 
battery power.

Selecting the Appropriate Light Setting

The meter has been pre-loaded with 9 light source selections (L0-L8) each 

having its own unique correction factor. See the light sources listed below. 

The correction factor multipliers for L0-L7 are fixed to the specific light 

sources listed, whereas, L8 is a customizable location which allows you 

to set your own correction factor if a high precision light meter with "V( )" 

<3% is available.

In order to select the appropriate setting, press the 

 button and press 

the   and   buttons to toggle through the list of light sources. When the 

appropriate light source has been selected, press the 

 button again to 

confirm your selection and resume normal operation.
Light Sources:
L0: Standard incandescent light source
L1: LED white daylight (5000K)
L2: LED AMBER (YELLOW) light (3000K)
L3: LED GREEN light
L4: LED RED light
L5: LED BLUE light
L6: Warm White Fluorescent Lamp (4000K)

continued...

1.800.561.8187 

[email protected]

REED-Direct.ca

Содержание R8140

Страница 1: ...www REEDINSTRUMENTS com LED Light Meter Instruction Manual R8140 1 800 561 8187 info REED Direct ca REED Direct ca ...

Страница 2: ... Operating Instructions 6 8 Power On Off Automatic Zero Adjustment 6 Unit of Measure Selection 7 Measurement Range Selection 7 Data Hold 7 MIN MAX 7 Auto Power Off 8 Backlight 8 Selecting the Appropriate Light Setting 8 9 Characteristics of Sensor Spectrum Response 9 Battery Replacement 9 Applications 10 Product Care 10 Product Warranty 10 Product Disposal and Recycling 11 Product Support 11 1 800...

Страница 3: ...ment Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Measures ambient light levels of white red yellow green and blue LED light and visible light in Foot candles or Lux Large backlit LCD display Detachable and rotatable li...

Страница 4: ...orescent Lamp Incandescent Angle deviation from cosine characteristics 10 1 30 2 60 5 80 20 Autoranging Yes Auto and Manual Display 6 digit LCD Backlit Display Yes Data Hold Yes Min Yes Max Yes Overrange Indicator Yes Auto Shut off Yes after 30 minutes Low Battery Indicator Yes Power Supply 2 x AA Batteries Battery Life Approx 80 hours Product Certifications CE RoHS Operating Temperature 32 to 104...

Страница 5: ...otective Cap 2 Light Sensor 3 LCD Display 4 Power Backlight Button 5 HOLD Button Display Description 6 MIN MAX UP Button 7 Range Selection Down Button 8 Set Button 9 Fc Lx Selector Button 10 Battery Cover 1 800 561 8187 info REED Direct ca REED Direct ca ...

Страница 6: ...not expose this meter to areas of high temperature and humidity Operating Instructions Power On Off Automatic Zero Adjustment 1 Push the Power Button to turn the meter on To turn the meter off press and hold the power button during the countdown cycle from 3 to 0 2 When turning the meter on it will perform an automatic zero adjustment as indicated by CAP on the LCD display Note Keep the protective...

Страница 7: ...s the button again to resume normal operation MIN MAX 1 Press the MIN MAX button to enter the MIN MAX function 2 The MAX indicator will appear on the display 3 Under this function the maximum light value is displayed and updated when a new maximum data value has been taken 4 Press the MIN MAX button again and the MIN indicator will appear on the display 5 Under this function the minimum light valu...

Страница 8: ...has been pre loaded with 9 light source selections L0 L8 each having its own unique correction factor See the light sources listed below The correction factor multipliers for L0 L7 are fixed to the specific light sources listed whereas L8 is a customizable location which allows you to set your own correction factor if a high precision light meter with V 3 is available In order to select the approp...

Страница 9: ...es proceed with the following steps 1 Turn off the meter 2 Remove the Phillips head screw located on the battery compartment 3 Remove the battery cover 4 Replace the 2 x AA batteries 5 Reinstall the battery cover Applications OSHA work environment compliance Cinematography and photography applications Museum exhibits Lighting system installation Environmental monitoring Interior design projects In...

Страница 10: ...ate of shipment During the warranty period REED Instruments will repair or replace at no charge products or parts of a product that proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments shall not be liable for damages to goods property or persons due to...

Страница 11: ...se contact your authorized REED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly ...

Страница 12: ...www REEDINSTRUMENTS com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS 1 800 561 8187 info REED Direct ca REED Direct ca ...

Отзывы: