background image

Non-Contact 

Voltage Detector

Instruction 

Manual

R5110

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Содержание R5110

Страница 1: ...Non Contact Voltage Detector Instruction Manual R5110 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30 ...

Страница 2: ...tions 5 6 Turning the Detector ON OFF 5 Turning the Flashlight ON OFF 5 AC Voltage Detection 5 High Low Voltage Detection Modes 6 Low Battery Indicator 6 Auto Power Off 6 Battery Replacement 6 Product Care 7 Product Warranty 7 Product Disposal and Recycling 8 Product Support 8 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30 ...

Страница 3: ...arranty Servicing should only be provided by an authorized service center Do not use the product if it appears to be damaged or isn t operating properly Do not apply more than the specified voltage Before each use verify operation by testing a known working circuit that is within the rating of this unit Operation may be affected by differences in socket design and type Low voltage mode 24V AC 1000...

Страница 4: ...0VAC Frequency Range 50 to 60Hz Built in Flashlight Yes Pocket Clip Yes Alarm Yes audio visual Auto Shut off Yes after 5 minutes Low Battery Indicator Yes Power Supply 2 x AAA batteries Overvoltage Category CAT IV 1000V Product Certifications CE ETL Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 4 to 122 F 20 to 50 C Operating Humidity Range 0 to 80 Max Operating Altitude 6561 200...

Страница 5: ...range is set to High 90 to 1000VAC Press and hold the power button again to turn the detector off Turning the Flashlight ON OFF Press the Flashlight button to turn the built in flashlight ON and OFF Please note the detector does not need to be powered on for the flashlight to function The flashlight will automatically turn off when the detector is not used for 5 minutes AC Voltage Detection Place ...

Страница 6: ...l interference noise Please only use low voltage mode during weak electrical field environment Low Battery Indicator When the battery voltage is lower than 2 4V the detector will automatically turn OFF Auto Power Off The detector will auto power off when it is not used for 5 minutes Battery Replacement 1 Hold the detector with one hand use your thumb of the other hand to press down on the battery ...

Страница 7: ...arranty period REED Instruments will repair or replace at no charge products or parts of a product that proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments shall not be liable for damages to goods property or persons due to improper use or through att...

Страница 8: ...ized REED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info REEDInstruments com Please visit www REEDInstruments com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly prohibited without pri...

Страница 9: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30 ...