background image

Thermocouple 

Calibrator

Instruction 

Manual

R2810

www.

.com

[email protected]

1.800.561.8187

Содержание R2810

Страница 1: ...Thermocouple Calibrator Instruction Manual R2810 www com information itm com 1 800 561 8187 ...

Страница 2: ...Auto Power Off 8 Selecting the Tempreture Unit of Measure C F 8 Output Function 9 Simulating DC Voltage Output 9 Simulating Thermocouple TC Output 9 10 Measure Function 10 11 Warning 10 Caution 10 11 Measuring DC Voltage 11 Measuring Thermocouples 11 Battery Replacement 12 Applications 12 Accessories and Replacement Parts 13 Product Care 13 Product Warranty 13 Product Disposal and Recycling 14 Pro...

Страница 3: ... Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center To avoid injury to the user or damage to the instrument please read the safety information below before initial use Do not operate the instrument around flammable or explosive gas va...

Страница 4: ...Functions Accuracy specified at 23 C 5 C 75 RH for a period of one year after calibration Output Range Output Range Resolution Accuracy DCV 100mV 10 00mV to 110 00mV 0 01mV 0 05 rdg 30µV 1V 0 1000V to 1 1000 V 0 1mV 0 05 rdg 0 3mV TC R 40 to 1760 C 1 C 0 05 rdg 3 C 100 C 0 05 rdg 2 C 100 C S 20 to 1760 C 1 C B 400 to 1800 C 1 C 0 05 rdg 3 C 600 C 0 05 rdg 2 C 600 C E 200 0 to 1000 0 C 0 1 C 0 05 r...

Страница 5: ...to 1200 0 C 0 1 C T 200 0 to 400 0 C 0 1 C N 200 0 to 1300 0 C 0 1 C General Specifications Display 6 Digit LCD Zero Adjustment Button Yes Kick Stand Yes Power Supply 2 AA Batteries Cold Junction Compensation Yes Auto shut off Yes after 15 minutes off Low Battery Indicator Yes Replaceable Test Leads Yes Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Operating Humidity Range ...

Страница 6: ... OUTPUT INPUT 1 LCD Display 2 POWER Button 3 Input Output Button 4 Zero Reset Button 5 Function Selection Output Button 6 Range Selection Button 7 RJ ON Button T C Cold Junction Compensation Button 8 Output Value Setting Button 9 Output Digit Selection Button 10 Input Output terminals www com information itm com 1 800 561 8187 ...

Страница 7: ...ument is in input mode Indicates that the instrument is performing its reference cold junction compensation Indicates battery power is low and batteries need to be replaced Indicates which output digit is being set Indicates unit of measure of current output value Indicates thermocouple type www com information itm com 1 800 561 8187 ...

Страница 8: ...tic power off function is enabled 6 Press the RJ ON button to save the required setting 7 Press and hold the POWER button to exit the maintenance state and turn the instrument off Selecting the Temperature Unit of Measure C F 1 Turn the meter off 2 Press the POWER button to display the full screen 3 Quickly press and hold the RANG button when the instrument is in the maintenance state as indicated...

Страница 9: ...0 0000V or 00 00mV 4 Press the button to select the set digits for output 5 Press the button to change the numerical value of the set digits Numerical value cannot be changed beyond the maximum range of the meter 6 Press the ZERO button and the output will be set to 00 00mV or 0 0000V Simulating Output from Thermocouple TC 1 Insert one end of the test lead into the OUTPUT terminal of the calibrato...

Страница 10: ...g ambient temperature do not start the operation until the built in compensating sensor has become stable approx 10 minutes If there is no need for the calibrator to perform automatic reference junction compensation press the RJ ON button and the symbol RJ ON will no longer appear in the display 8 Press the ZERO button and the output will be directly set to 0000 C R or S type 400 C B type or 0000 ...

Страница 11: ...esh rate is twice a second and if the measured value exceeds the measurement range the LCD displays OL Measuring Thermocouples 1 Insert one end of the test lead into the INPUT terminal of the meter and connect the other end to the output terminal of the instrument under test as shown in the diagram above 2 Press INPUT OUTPUT button to select the Input function 3 Press the FUNC button to select the...

Страница 12: ...tteries in the lid of the battery compartment 4 Reinstall the compartment lid by ensuring that the battery terminals touch the unit s contact points and snap into place 5 Tighten the screw to secure the battery compartment door Note Ensure battery door is closed and secured in place before using the meter To ensure proper operation please wait 5 seconds before turning meter on after changing batte...

Страница 13: ...duct Warranty REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one 1 year from date of shipment During the warranty period REED Instruments will repair or replace at no charge products or parts of a product that proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liabi...

Страница 14: ...t your authorized REED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly prohibite...

Страница 15: ...Test Measure with Confidence Check out our latest Products www com information itm com 1 800 561 8187 ...

Страница 16: ...www com information itm com 1 800 561 8187 ...

Отзывы: