background image

10

Product Disposal and Recycling

Please follow local laws and regulations when disposing or recycling your 

instrument. Your product contains electronic components and must be 

disposed of separately from standard waste products.

Product Support 

If you have any questions on your product, please contact your authorized 
REED distributor or REED Instruments Customer Service by phone at 
1-877-849-2127 or by email at [email protected].

Please visit 

www.REEDINSTRUMENTS.com

 for the most  

up-to-date manuals, datasheets, product guides and software.

Product specifications subject to change without notice.  

All rights reserved. Any unauthorized copying or reproduction of  

this manual is strictly prohibited without prior written permission 

from REED Instruments.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 800837000651

Страница 1: ...Scale Durometer Instruction Manual HT 6510A www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...oint Calibration 8 Battery Replacement 9 Accessories and Replacement Parts 9 Product Care 9 Product Warranty 9 Product Disposal and Recycling 10 Product Support 10 Introduction Thank you for purchasin...

Страница 3: ...e of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Shore A hardness tester...

Страница 4: ...ons Yes Power Supply 2 x AAA Batteries Low Battery Indicator Yes Product Certifications CE Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 4 to 140 F 20 to 60 C Operating Humidity Rang...

Страница 5: ...0A S H O RE A HARDNESS TES T E R 1 Battery Cover 2 Zero Button 3 Max Hold Button 4 LCD Display 5 Average Measaurement Button 6 POWER Button 7 Presser Foot 8 Indenter www GlobalTestSupply com Find Qual...

Страница 6: ...o check accuracy simply insert the indenter into the hole of the calibrated test block 3 Apply enough force to make enough contact between the top surface of the test block and the presser foot 4 The...

Страница 7: ...MAX button to exit maximum measurement mode and resume normal operation Average Measurement Mode The average value is calculated using the number of test measurements the user selects which can range...

Страница 8: ...med to turn itself off after 10 minutes of inactivity Zero Calibration Press the ZERO button to perform a zero calibration when required Single Point Calibration 1 Place the indenter onto a flat test...

Страница 9: ...l parts only Product Warranty REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one 1 year from date of shipment During the warranty period R...

Страница 10: ...D distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets pr...

Страница 11: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 12: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Отзывы: