background image

  Installation Instructions 

 

 

 

Posh Solus MK3 Shower Mixer with Extended Lever

 

Mixer must be installed to the requirements of AS/NZS 3500 by a quali

fi

ed plumber. Your mixer comes to you 

already factory assembled and tested. We do not recommend the dismantling of any internal part of the mixer. 
The mixers are factory tested and sealed so as to give the best performance.

 

Installer is responsible for ensuring water connections to the mixer body are watertight.

 

INSTALLATION REQUIREMENTS:

 

1.

 

Flush out new pipe work prior to connecting the new mixer.

 

2.

 

Mixer body (7) must be installed onto a noggin or mounting plate in the wall and be 

fi

xed using suitable 

mounting screws (not supplied). Provisions must be made by the installer to ensure the mixer body (8) is 
mounted vertically level.

 

3.

 

Hot water supply must be connected to the ‘H’ marked inlet and the cold-water supply must be connected 
to the ‘C’ marked inlet.

 

4.

 

Mixer body must be installed with the outlet facing upwards. For bath spout outlet connections, pipe work 
must be redirected around the mixer body.

 

5.

 

If installing the mixer to a bath, then outlet must point upward, and water line must be toward the shower.

 

6.

 

Cover plate (2) is designed to sit 

fl

ush when the mixer body is installed to a level 

fi

nish wall.

 

7.

 

After the cover plate (2) has been 

fi

tted, assemble the handle (1) using a 1.5 mm Allen key and 

fi

t the diverter

 

(6) to the diverter socket.

 

NOTE:

 

 

Mixer must be installed only with pressurised hot water storage and instantaneous water systems 

only

 

 

Tile dome and diverter tile plug must only be removed when it’s time to 

fi

t the cover plate, handle 

and diverter

 

SERVICING - REPLACEMENT OF CARTRIDGE:

 

1.

 

Disassemble the handle (1) from the mixer body by removing the locking grub screw cap and unscrewing 
the locking grub screw with a 1.5 mm Allen key.

 

2.

 

Unscrew the cartridge dome (3) and use a wrench to unscrew the cartridge locknut (4).

 

3.

 

Remove and replace the mixer cartridge (5). Reassemble the locknut (4), cartridge dome (3) and handle 
assembly (1).

 

4.

 

Test reassembled mixer for leaks.

 

CLEANING RECOMMENDATIONS

 

We recommend the use of soapy water or approved cleaners. 
This product should not be cleaned with abrasive materials.

 

Damage caused by any improper treatment is not covered by the product warranty - refer to Warranty Condi- 
tions.

 

Please ensure a copy of the installation instructions is left with the end user for future reference.

 

 
 
 
 
 
 
 
 

 