INSTALLATION 

INSTRUCTIONS 

AND MAINTENANCE

GUIDE

T-604 WASTE DISPOSER

Содержание Ciclon L T-604

Страница 1: ...INSTALLATION INSTRUCTIONS AND MAINTENANCE GUIDE T 604 WASTE DISPOSER...

Страница 2: ......

Страница 3: ...not open the upper lids Do not manipulate the interior of the sanitary waste disposer Always seek qualified and professional help WARNING For the purpose of avoiding possible fires and elec trocution...

Страница 4: ...ion Do not employ cleaning products containing solvents or acids When long non use periods are expected disconnect the plug from the socket Take care to turn off the stopcock preventing water supply t...

Страница 5: ...ted to the auxiliary inlet connection Sewage and waste materials pass into the unit and increase the water level The pressure micro switch comes on and the pump motor is activated Depending on the hei...

Страница 6: ...receives water from the sanitary appliance by the action of gravity The graded waste pipe from the basin shower or other fixture into the the waste disposer must have a positive grade to allow drainag...

Страница 7: ...by means of thermal insulation CONNECTION TO THE SEWER The connection to the sewer must be carried out by means of an inclined or oblique branch If the connec tion to the sewer is at a lower level tha...

Страница 8: ...harge to check the operation of the pumped discharge evacuation process After the discharge there should be no pieces of toilet paper left within the toilet bowl 6 INSTRUCTIONS FOR END USERS Once inst...

Страница 9: ...g a good quality non corrosive mild soap and damp cloth In areas with a high level of water hardness and for the purpose of eliminating the lime deposits it is recommended to regularly clean the appli...

Страница 10: ...lve is blocked The auxiliary connection lacks ventilation The micro switch that activates the pump is not working properly Clean the waste pipe from the auxiliary connection and the non return valve I...

Страница 11: ...he steps in reverse order see electrical connections be low and replace the cassette cover The whole process should take 10 minutes INSTALLATION INSTRUCTIONS AND MAINTENANCE GUIDE 9 Reece Product Code...

Страница 12: ...l in order to move the pipe and to make the dismantling easier Have a container nearby to collect water Empty the discharge pipe by activating the non return valve clapper Remove the clip nut Check or...

Страница 13: ...d discharge 6 m Max Graded distance of pumped discharge 62 m Dimensions and weight m m 250 x 300 x 530 s n o i s n e m i D 10 8Kg t h g i e W Weight incluiding packaging 12 2Kg NOTICE All data provide...

Страница 14: ...T AAV B DISCHARGE PIPE 25MM PVC PRESSURE PIPE 1 1 100 GRADIENT C INLET WASTE PIPE 2 5 1 40 GRADIENT D LOCATION OF POWER SUPPLY MUST BE IN ACCORDANCE WITH AS NZS 3000 AND MUST BE INSTALLED BY A LICENCE...

Страница 15: ...CARBON TANK LID 15 TANK FACING LID 16 CASSETTE FACING LID 17A CASSETTE 17B CASSETTE GASKET JOINT 18 MOTOR VENTILATION COVER 19 NUT 1 1 4 20 DETACHABLE PIECE OF CASSETTE FACING 21 PVCb PIPE 22 PLASTIC...

Страница 16: ...MOTOR VENTILATION CASING 5 THREE WIRE CABLE 6 ENTRY BOOTS 7 MOTOR 8 MOTOR INSULATING DISC 9 PRESSURE SWITCH W SCREW 10 22x3 O RING 11 SCREW MOTOR PLUGS 12 MOTOR FIXING SCREW 13 CERAMIC LOCK 14 ROTOR 1...

Страница 17: ...FICATION FOR PLUMBING AND DRAINAGE PRODUCTS PART 101 APPLIANCES LOW HAZARD RATING TESTED TO EUROPEAN STANDARDS EN 12050 3 WASTE WATER LIFTING PLANTS FOR BUILDINGS AND SITES PRINCIPLES OF CONSTRUCTION...