26
PROBLEM: The walking belt is off-center or slips when walked on
SOLUTION:
a. If the walking belt is off-center, first remove the key
and
UNPLUG THE POWER CORD
.
If the walking
belt has shifted to the left,
use the allen wrench to
turn the left rear roller bolt clockwise 1/2 of a turn;
if
the walking belt has shifted to the right,
turn the
bolt counterclockwise 1/2 of a turn. Be careful not to
overtighten the walking belt. Plug in the power cord,
insert the key and run the treadmill for a few minutes.
Repeat until the walking belt is centered.
b. If the walking belt slips when walked on, first remove
the key and
UNPLUG THE POWER CORD
. Using
the allen wrench, turn both rear roller bolts clockwise,
1/4 of a turn. When the walking belt is correctly tight-
ened, you should be able to lift each side of the walk-
ing belt 3 to 4 inches off the walking platform. Be
careful to keep the walking belt centered. Plug in the
power cord, insert the key and carefully walk on the
treadmill for a few minutes. Repeat until the walking
belt is properly tightened.
PROBLEM: The incline of the treadmill does not change correctly or does not change when iFIT.com
CDʼs and videos are played
SOLUTION:
a. With the key inserted in the console, press one of the Incline buttons.
While the incline is
changing, remove the key.
After a few seconds, re-insert the key. The treadmill will automati-
cally rise to the maximum incline level and then return to the minimum level. This will recalibrate
the incline.
PROBLEM: The chest pulse sensor does not function properly
SOLUTION:
a. If the chest pulse sensor does not function properly, see CHEST
PULSE SENSOR TROUBLESHOOTING on page 10.
b. If the chest pulse sensor still does not function properly, the battery
should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.
Next, remove the old battery from the sensor unit. Insert a new
CR
2032 battery
, making sure that the writing is on top. In addition,
make sure that the rubber gasket is in place in the sensor unit.
Replace the battery cover and turn it to the closed position.
b
a
CR2032
Battery
Rubber
Gasket
b