background image

 

M003 Issue: 1.5 Created by: Technical Dept. 

February 2020 

Contents: - 

1.0 

  Introduction 

 

2.0 

  Lightbar Specification 

 

3.0 

  Power Specification 

 

4.0 

  LBAR Main Controller 

 

 

 

4.1 Input / Output functions 
4.2 Wiring and Connectivity 

 


5.0 

  Setting the Flash Pattern 

 

6.0 

 

5.1 360 Output 1&2 
5.2 Alley Lights 

CAP168 / ICAO / CAA / ACAA / Airport mode 

 


7.0 

  Setting Dim Mode 

 

5-6 

8.0 

  ECE R65 Monitor Output 

 

9.0 

  Setting the Colour 

 

10.0 

  Programming the Lightbar 

 

 

 

10.1 Setting an Input function (F1-F9) 
10.2 Reset Input 

 


     11.0 

  Traffic Director 

 

 

 

11.1 TDIR Rear Only 
11.2 Changing Traffic Director Operation 
11.3 Warning Lamp Mode 
11.4 Setting Traffic Director Length 
11

.5 Enable ‘Chase’ M

ode 

 





12.0 

  Additional Programmable Inputs 

 

 

 

12.1 Front/Rear Split 
12.2 Cruise Mode 
12.3 Front Flood Takedown Flash 
12.4 Front Floods 
12.5 Stop lamp 
12.6 Tail lamp 
12.7 Left Indicator 
12.8 Right Indicator 
12.9 Rear Worklamp 
12.10 Rear Worklamp 

 Set front / rear operation 

12.11 360 Worklamp 
12.12 Flexi-Flash 
12.13 Changing Flexi-Flash Operation 
12.14 Setting Flexi-Flash Modules 
12.15 Inclusion / Exclusion flag 

 





10 
10 
10 
11 
11 
11 
10 
10 
10 
11 

13.0 

  Upgrades 

 

15 

 

 

13.1 LED Modules 
13.2 Alley Lights 

 

15 
17 

14.0 

  Fuse Requirements 

 

18 

15.0 

  Synchronisation 

 

19 

16.0 

  Restore Factory Settings 

 

19 

17.0 

  Cleaning the Lightbar 

 

20 

18.0 

  Troubleshooting 

 

21 

19.0 

  Additional Equipment 

 

21 

 

  Appendix 1 

 

Dipswitch settings

 

 

22 

 

  Appendix 2 

 

Diagnostics

 

 

22 

 

  Appendix 3 

 

Spare Parts / List Pricing

 

 

23-24 

 

  Glossary of Terms 

 

25 

Содержание BULLITT ADVANCED

Страница 1: ...hod to ensure customers cannot accidentally change feature settings Added information on setting up Stop Tail Indicator lamps Improved explanation of features Explanation of dipswitch settings on mast...

Страница 2: ...Director Length 11 5 Enable Chase Mode 8 8 8 8 8 12 0 Additional Programmable Inputs 9 12 1 Front Rear Split 12 2 Cruise Mode 12 3 Front Flood Takedown Flash 12 4 Front Floods 12 5 Stop lamp 12 6 Tail...

Страница 3: ...itt Advanced Lightbars are manufactured to operate within the voltage range of 10 30v DC negative ground ve earth This will require setting upon installation to ensure correct functionality Supply Vol...

Страница 4: ...echnical Dept 3 February 2020 Standby Mode 4 0 LBAR Main Controller There are nine programmable inputs F1 F9 available to programme a variety of 23 optional features 4 1 Input Output functions 4 2 Wir...

Страница 5: ...Left Right 10 Triple Mix Mode 3 Double Left Right 11 Double Mix Mode 4 Single Left Right 12 Single Mix Mode 5 Quad All On 13 Quad In Out 6 Triple All On 14 Triple In Out 7 Double All On 15 Double In O...

Страница 6: ...rent flash modes left right all on mix in out In addition the colour can be individually set to each output refer to 9 0 Setting the Colour 6 1 360 1 360 2 Outputs a Ensure the Lightbar is in Standby...

Страница 7: ...nce This is a positive output that will drive upto 500mA at nominal voltage supply Please do not put a heavy load to this wire connection When there is non compliance to the standard the signal will d...

Страница 8: ...ft 3 F1 Main Traffic Director Left Right 4 F2 Main Traffic Director Right Centre 5 F3 Main Traffic Director Centre Rotate 6 F6 Rotate Ends Front Only 7 Flash Front Only Rear Only 8 F5 Flash Rear Only...

Страница 9: ...yellow wires 11 3 Warning Lamp Mode a Ensure the Lightbar is in Standby mode b Apply the orange purple wires to ve permanently If more than one TDIR function is selected the Lightbar will resort to a...

Страница 10: ...rnate the flash mode against 360 1 360 2 flexi flash or other mode if not restricted simple apply the brown Pattern Select wire to ve for five 5 seconds this will alternate the flash pattern against t...

Страница 11: ...arious lamp positions at this stage with a maximum length of 1 full module the modules split into half to allow for STI setup using BL ADSTI each time it will return to the centre to allow you to sele...

Страница 12: ...ection 10 1 selecting feature code 22 for Rear Worklamp b Apply the yellow sync wire to ve permanently c Apply the grey Config wire to ve permanently d Apply the brown wire to ve momentarily until the...

Страница 13: ...the programmed Flexi Flash input wire to ve permanently c Apply the yellow sync wire to ve permanently d Apply the grey Config wire to ve permanently e Apply the blue Dim wire to ve permanently f Appl...

Страница 14: ...M003 Issue 1 5 Created by Technical Dept 13 February 2020 Fig 1 Fig 2...

Страница 15: ...m flashing whilst the Blue lights are active on 360 1 a With the Lightbar in Standby mode b Apply the relevant function wire to ve permanently for instance as 360 2 c Apply the grey wire to ve permane...

Страница 16: ...s you require are possible before proceeding When carrying out any upgrade the Lightbar should ideally be de installed from the vehicle Where this is not practicable the Lightbar MUST be isolated from...

Страница 17: ...by Technical Dept 16 February 2020 d Connect the module to the existing string via the 4 way connector e If the string contains four 4 or more LED modules the return connector loom on the LBAR Main C...

Страница 18: ...ernal stock code S EM315WC BL a Carefully remove the M4 and M6 socket cap screws and washers from the top lenses and place to one side b Remove the top lenses and place carefully to one side Ensure th...

Страница 19: ...roximately half the current shown in the table below Installers should contact their sales representative if unsure of the fusing requirements Lightbar Size Type No of LED s Flash Pattern 3 Watt Max C...

Страница 20: ...tings In extreme cases it may be necessary to restore the Lightbar to factory settings a Ensure the Lightbar is in Standby mode b Apply the brown Pattern Select wire to ve permanently c Apply the blue...

Страница 21: ...distance of the pressure washer nozzle from the lightbar is 15cm Ensure the water pressure does not exceed 100 bar Ensure the water flow rate does not exceed 15 litres min Ensure the water temperature...

Страница 22: ...rogrammed Refer to 10 0 Programming the Lightbar to re enable excluded LED modules All LED s flash at the same time blinking CAP168 Airport mode enabled De select dipswitch 2 Change flash pattern Appl...

Страница 23: ...4 F2 Main Traffic Director Right Purple 4 short flashes Centre 5 F3 Main Traffic Director Centre Pink 1 long flash Rotate 6 F6 Rotate Ends White Brown 1 long 1 short flash Front Only 7 Flash Front Onl...

Страница 24: ...ODULE 10 59 93 BL ADSBN BULLITT ADVANCED 6 LED BLUE LED MODULE 10 59 93 BL ADSRN BULLITT ADVANCED 6 LED RED LED MODULE 10 59 93 BL ADSGN BULLITT ADVANCED 6 LED GREEN LED MODULE 10 59 93 BL ADSWN BULLI...

Страница 25: ...ENTARY CIGARETTE PLUG 4 28 57 EM173CGD2 LATCHING LATCHING CIGARETTE PLUG 4 28 57 EM173RFSS SUPER STRONG MAGNET 10 17 86 FASTWM4ZPN M4 WASHER ZINC PLATED 100 0 13 FASTWM6CSN M6 WASHER CARBON STEEL 100...

Страница 26: ...9 Programmable Inputs ft lb Foot Pounds fpm Flashes Per Minute Gnd Ground high current connector in lb Inch Pounds IP Ingress Protection Rating Inclusion Flag Enable Disable programmed function as par...

Отзывы: