Changing ‘DIP Switch’ Default Setting
On the PCB in the upper right corner there is a set of 6 ‘DIP Switches’ (See
NOT TO BE CHANGED
they are used for the shower software configuration.
Diagram 9) The top 3 are
WARNING!
Switch OFF the electricity at the isolating switch before removing the cover.
9
10mm
55mm
EARTH
LIVE
NEUTRAL
FIT EARTHING SLEEVE
Diagram 7
IMPORTANT Connect flying lead from PCB
to rear of the front cover - see
Remember to select mode and configure
before, replacing the front cover and fastening
in position with four screws.
Diagram 6.
Changing The Operating Mode
Templock/Normal
On the extreme right hand side of the PCB
mid way up is the
‘4 Way Temp Limit Slider
Switch’
(See Diagram 8).
PLEASE NOTE!
The Selectronic Premier is
factory set with the ‘Temp Limit Slider Switch’
set at ‘Locked Position 1’.
After the unit is commissioned, you have the
option of choosing from any of three different
lockable temperature settings plus normal
operation position from left to right.
Remove the front cover taking care not to strain
the flying lead.
Change the switch to the desired temperature
control position.
WARNING!
Switch OFF the electricity
at the isolating switch before removing
the cover.
Replace and refasten the front cover.
Switch on electricity. Check that the unit operates correctly.
PLEASE NOTE!
The Temperature Lock light on the front cover of the shower will not illuminate if
Normal Position 4 has been selected.
Locked
Position 1
(Extreme Left)
Unlocked
Position 4
(Extreme Right)
Temperature
Adjustment Range
34-40 C Nominal
°
25-46 C
°
Nominal
Locked
Position 2
(First ‘Click’ from
the Extreme Left)
Locked
Position 3
(Second ‘Click’ from
the Extreme Left)
34-41 C
°
Nominal
34-43 C
°
Nominal
Diagram 8
LOCKED
POSITION
’1’
LOCKED
POSITION
’2’
LOCKED
POSITION
’3’
UNLOCKED
POSITION
’4’
(For Top and Bottom entry : If 16mm² is
required, then use 10mm² just for the last link
from the Local isolator to the Shower).
Note : Ref 16mm² cable:
16mm² cable can only be installed via rear entry method.
*