background image

MODELOS

RP17PT      RP27PT

MONOFÁSICOS

Para servicio e instalación, póngase en contacto con:

  Bosch Water Heating

340 Mad River Park
Waitsfield VT 05673

LLAMADA GRATUITA

800-798-8161

     www.boschpro.com

IMPORTANTE: Este manual de 
instrucciones debe ser entregado al
cliente después de la instalación y
demostración del equipo.

Powerstream Pro  
LIMITED 10 YEAR WARRANTY  

(Continued from Page 11)

 

 

3. 

Verification of Date of Original Installation  – When owner cannot verify or document the original date 
of installation, the warranty period begins on the date of manufacture marked on the tag affixed to 
the water heater. 

 

EXCLUSIONS 

1. 

THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE 
MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR 
IMPLIED (WHETHER WRITTEN OR ORAL), INCLUDING, BUT NOT LIMITED TO, WARRANTIES 
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

 
2. 

Manufacturer shall not be liable for incidental, consequential, special or contingent d amages or 
expenses arising, directly or indirectly, from any defect in the water heater or the use of the water 
heater. 

 
3. 

Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect 
in the water heater component part(s) or from its use. 

 
4. 

Manufacturer shall not be liable under this warranty if:  
a) 

The water heater or any of its component parts has been subject to misuse, alteration, neglect 
or accident, or; 

b) 

The water heater has not been installed in accordance with the  applicable local plumbing 
and/or building code(s) and/or regulation(s), or; 

c) 

The water heater has not been installed in accordance with the printed manufacturer’s 
instructions, or; 

d) 

The water heater is not continuously supplied with potable water.  

 
5. 

The owner and not the manufacturer or his representative shall be liable for and shall pay for all field 
damages for labor or other expenses incurred in the removal and/or repair of the product or any 
expense incurred by the owner in order to repair the product. 

 

SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR 

 

CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO 
YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE 
OTHERS.  

IMPORTANT: OWNER SHALL KEEP THIS CERTIFICATE

NOTE:

   A water heater should be installed in such a manner that if it should leak, the resulting flow of 

water will not cause damage to the area in which it is installed.  

 

The person who initially installed the unit is the best one to con tact for help. 

You can also call 

BBT

 toll free at 800-798-8161. Please have this guide with you when you call.

 

 

 

12

.

14

.

05

 

© 

2005 Bosch Water Heating

                                                                         

555-2028-0

3A

                                             

Waitsfield, VT all rights reserved

 

12 

Содержание RP17PT

Страница 1: ...os...

Страница 2: ...et water temperature it can handle is 86 degrees F Contact Bosch Water Heating before specifying or installing the appliance in any other application 10 Additional Canadian safety instructions a As pe...

Страница 3: ...thermal cut outs which will operate if the unit overheats If a thermal cut out trips then it must be reset by a qualified electrician If the unit has been used recently run the water through for a few...

Страница 4: ...cold water supply and not to pre heated wate r The inlet water temperature must not be greater than 86 F The unit should be installed with shut off valves on both the inlet and outlet connections It i...

Страница 5: ...mended wire size is 8 AWG The terminal block will accept cables up to 6 AWG size The cable entry is via the 1 inch cable entry hole on the bottom right hand edge of the backplate Strip back the insula...

Страница 6: ...the L1 terminals in the unit There are two red wires required in the RP17PT and three in the RP27PT Connect the blue wires from the right hand terminal of the new block to the L2 terminals in the uni...

Страница 7: ...ntrol PCB for RP27PT 93 793779 Adjustment knob 93 793784 Inlet filter For further information ask your local deale r FOR SERVICE AND INSTALLATION QUESTIONS CALL TOLL FREE 800 798 8161 Toll Free Fax 80...

Страница 8: ...will be lower than what is shown in Graph 1 If a higher outle t water temperature is desired then reduce the flow rate and or supply the unit with 240 volts IMPORTANT Before leaving the site the inst...

Страница 9: ...average of 55 F Diagram 4 Internal wiring schematic for single phase PR27PT unit RP17PT has two heater modules and two supplies In Canada an auxiliary terminal block is fitted during installation CUTO...

Страница 10: ...y pushing the button s on the top of the heater module s Establish and fix the cause of the overheating Plumbing crossover Test by turning cold water supply off to heater then open hot water faucet s...

Страница 11: ...heater to the original owner of the water heater at the original installation location against defects in material and workmanship for the periods specified below WARRANTY PERIOD 1 The Heat Exchanger...

Страница 12: ...accident or b The water heater has not been installed in accordance with the applicable local plumbing and or building code s and or regulation s or c The water heater has not been installed in accord...

Отзывы: