Appendix Flow vs. Temperature Setting Guide:

 

 

The following graph Indicates the water temperatures the Thermostatic Powerstream Pro can 
achieve at different flow rates.  The graph shows the maximum and minimum temperatures 
achievable for the 12 kW unit with the inlet water temperature set to an average ambient 
temperature. 

 

 

 
 
 
 

NOTE: 

1.  As water temperature varies throughout the year adjustments to the Temperature 

Adjustment Spindle and/or the flow rate may be required. 

2.  We recommend the flow rate through the heater is set to the 

Winter Maximum

 

temperature (see graph above).  The heater will then maintain the set temperature in the summer 
months reducing the power automatically. 

Uso del Powerstream Pro 

Advertencia

 

No utilice esta unidad si cree que se puede 
congelar, ya que se podría dañar gravemente la 
unidad. Espere hasta que esté seguro de que se haya 
descongelado completamente antes de encenderla. 

Sumidero

 

• 

Compruebe que está conectado el suministro 
eléctrico en el panel de interruptores. 

• 

Abra COMPLETAMENTE la llave de agua 
caliente. Si no abre totalmente la llave, 
comprobará que la temperatura del agua puede 
variar.  La temperatura del agua caliente se puede 
cambiar con el disco de temperatura y ajustando 
correctamente el caudal. Consulte el apéndice 10 
para la relación correcta entre caudal y 
temperatura. 

• 

Si se ha utilizado recientemente la unidad, deje 
circular el agua unos segundos para que se 
estabilice la temperatura. Es posible que se 
produzca una descarga corta de agua muy caliente 
de la unidad. 

• 

Si también se abre una segunda salida conectada 
a la unidad, el agua caliente será compartida entre 
las dos salidas, por lo que el caudal y/o la 
temperatura del agua disminuirá. 

 

Instalación del Powerstream Pro 

Advertencia

 

No instale el Powerstream Pro en una habitación: 
donde se pueda congelar. 

IMPORTANTE 

– Lea las instrucciones 

completas. Compruebe la presión del suministro de 
agua principal.  Para que el funcionamiento sea 
correcto, la unidad requiere las presiones de 
funcionamiento siguientes: 

Sumidero

 

Mín:    1,4 bar 
Máx:   10,3 bar 

Instalación de la unidad en la pared 

Selección de la posición

 

• 

Si la unidad se utiliza en un área pública, realice 
su montaje de forma que no se llegue fácilmente 
a la unidad, con el fin de impedir el vandalismo. 

• 

Monte la unidad en una sección plana de la 
pared, alejada de las posibles salpicaduras de 
agua. 

• 

Coloque la unidad a lo largo (diagrama 1). 
Reduzca al mínimo la longitud del tubo de agua 
caliente para ahorrar energía. 

• 

Si la unidad va a suministrar agua en un 
sumidero, puede instalarla por encima o por 
debajo de éste. 

Advertencia

 

La unidad se debe montar según se ilustra 
La colocación se debe efectuar ‘a lo largo’ con las 
uniones de las tuberías orientadas hacia abajo.  En 
ningún caso se deben montar la unidad de forma 
diferente. 

 

 
 

 

Diagrama 1

Fría

Caliente

Fría

Caliente

Fría

Caliente

Vista desde la parte posterior

Содержание RP12PT

Страница 1: ...ostatic MODEL RP12PT 240V For Service Installation contact 340 Mad River Park Waitsfield VT 05673 800 798 8161 www boschpro com IMPORTANT This booklet should be given to the customer after installatio...

Страница 2: ...s completely thawed cut 9 The Powerstream Pro is designed to heat potable cold water for domestic purposes Contact Bosch Water Heating before specifying or installing the appliance in any other applic...

Страница 3: ...ater will be shared between the two therefore the flow and or the temperature of the water will decrease Installing the Powerstream Pro Warning Do not install the Powerstream Pro in a room where there...

Страница 4: ...led with service valves on both the inlet and outlet We recommend that you use copper or high pressure flex connections Use Teflon tape for sealing pipe threads Do NOT use pipe dope Remember to keep t...

Страница 5: ...within sight of the appliance REF NEC 422 31 Make sure that all the terminal block screws are tightened securely Loose connections can cause wires to neat up Make sure that the ground wire is wrapped...

Страница 6: ...outlet temperature is correct Check that the unit works correctly when the sink tap is closed and then opened again if not adjust the service valve slightly The outlet shut off valve can be used to re...

Страница 7: ...rature dial A badly set flow rate can also have a negative effect on the temperature Depending on the region of the country the temperature of the water supply can varyfrom 40 F in winter to about 70...

Страница 8: ...er and observe if the flow switch activates when the water is turned on If not contact BBT 800 798 8161 www boschpro com Water flow too high for unit to control Adjust water flow to recommended flow r...

Страница 9: ...l on the front of the cover Cold water only neon light on The inlet water temperaturehas dropped Adjust the flow rate Water flow rate too low or temperature too high The hot tap is not fully open Adju...

Страница 10: ...the 12 kW unit with the inlet water temperature set to an average ambient temperature NOTE 1 As water temperature varies throughout the year adjustments to the Temperature Adjustment Spindle and or th...

Страница 11: ...11...

Страница 12: ...nufacturer shall not be liable under this warranty if a The water heater or any of its component parts has been subject to misuse alteration neglect accident or freeze or b The water heater has not be...

Отзывы: