background image

Redring After Sales Service 

 

We offer a technical advisory service to installers and other customers with problems in the 
field. 

RING: 0844 372 7766    /   FAX: 0844 372 7767 

 

Some Spare parts (see later section) can be supplied against any debit or credit cards. 

 

Remember to quote the exact type of shower, as written on the front of the shower and on this 
leaflet.  
The model and serial number are located on the bottom face of the shower.                                                         
Make a note of these numbers here, and be sure to quote them if you call for advice.  

 

Model Number: 53- . . . . . . . . . . . .  / Serial Number:  . . . . . . . . . . . . .   

 

Note: You may be charged for a service call if you do not have the serial number. 

 

Additional Accessories 

 

 

Catalogue Number 

 

WRAS water isolating valve 

 

 

 

93-792452 

Curtain and rail pack 

 

 

 

 

83-792812 

 

Spares 

 

 

 

 

 

Catalogue Number 

 

Please Note:- The fitting of spare parts must be supervised by a suitably qualified person 

 

Front cover complete (650 white) 

93-597881 

Front cover complete (650 plated version) 

93-597814 

Control knob (650 white) 

93-597815 

Plated control knob (650 plated version) 

93-593590 

Gear drive 

93-593591 

Outlet elbow assembly complete. 

93-593592 

Thermal cutout 

93-590306 

Solenoid 

93-591805 

Inlet elbow 

93-591804 

 

Removable side section (grey) 

93-593593 

Removable side section (white) 

93-591819 

 

Spares / accessories can be supplied against any Credit or Debit cards from  
Redring Sales Hotline: Tel 0844 372 7750 / Fax 0844 372 7760.  

 

Energy Related Product Directive (ErP) 

 

 

This information shows how our products pass the relevant European Union Energy Directives

 

 

 

Manufacturer 

Redring 

Product 

R6508 

R6508C 

R6509 

R6509C 

R65010 

Load Profile 

XS 

XS 

XS 

Efficiency Class 

Efficiency % 

39 

39 

39 

Consumption                          
(kWh / annum) 

471 

468 

470 

Sound (dB) 

15 

15 

15 

Precautions 

Please ensure all product installation, maintenance and care instructions 

are followed as per the instructions listed here

 

10 

Содержание R65010

Страница 1: ...Shower Handbook Also covers 650 chrome variant IMPORTANT Please retain this booklet for future reference ...

Страница 2: ... mains water temperature between summer and winter 6 When you have finished showering push button D only The electricity to the elements is then disconnected and the adjacent light will flash water will continue to flow for approximately 5 seconds before switching off This reduces the temperature of the water in the unit Switch the electricity off at the ceiling switch or local isolator 7 Your sho...

Страница 3: ...ter 3 The heaters are only switched on when sufficient water is flowing This is done automatically with a switch which works on water pressure 4 The water is turned on and off by the solenoid valve built into the shower This is switched on by button A B or C diagram 1 5 The flow of water is automatically held at the level set by the user even though the supply pressure may vary See How to use your...

Страница 4: ...out e g another tap drawing water off Raise position of handset e Broken parts Please contact our spares department on 0844 372 7750 Fitting instructions are provided with spares PROFESSIONAL SERVICE If the previous checks fail to restore the performance you should seek professional help The person who installed the shower is probably the best one to repair it and is certainly the person to contac...

Страница 5: ...ons sheet then a vacuum breaker must be fitted 4 Fix the riser rail with screws provided The fixing holes at the base of the brackets will be disclosed by removing the plastic fronts Assemble as shown in diagram 13 5 Decide the position of the electrical cable inside the unit If top or bottom entry is chosen according to diagram 5 cut away the walls of the back plate as shown in diagram 7 There is...

Страница 6: ...minimum running pressure of 100kPa 1 0 bar 14 5 p s i and a maximum pressure of 1000kPa 10 bar 145 p s i Before connecting the pipe work to the shower ensure that pipe work is flushed out 1 It is recommended that a WRAS Water Regulations Advisory Scheme listed isolating valve is fitted between the rising main and the unit This will allow the unit to be serviced without turning off the cold water o...

Страница 7: ...movable side section are fitted WARNING DO NOT FIT A TAP ON THE SHOWER OUTLET TAKE CARE TO AVOID RESTRICTING THE OUTLET AND FLOW FROM THE SHOWERHEAD OR THE PRESSURE RELIEF DEVICE c Electrical Connections The electrical installation must be in accordance with the current BS 7671 IEE regulations and Part P of the Building Regulations and or local regulations 1 The shower is designed for a single pha...

Страница 8: ...AVOID DAMAGING ANY COMPONENTS 8 Operate the shower first without the handset to flush out particles fit handset and then operate the shower as explained previously and check a That the water gets to a satisfactory temperature b Power selection does give a change in water temperature c Check again for leaks d That the holes in the spray plate are not blocked e Water flow can be adjusted by knob E 9...

Страница 9: ...ARLY DESCALE THE SHOWER HANDSET There are a number of defined spray plate settings modes patterns adjustable by rotating the spray plate The modes patterns have a positive click to identify them The spray plate rotates through a full circle 360 in either direction to change the spray pattern All water contains particles of lime scale which build up in the shower handset and unit reducing the perfo...

Страница 10: ... supervised by a suitably qualified person Front cover complete 650 white 93 597881 Front cover complete 650 plated version 93 597814 Control knob 650 white 93 597815 Plated control knob 650 plated version 93 593590 Gear drive 93 593591 Outlet elbow assembly complete 93 593592 Thermal cutout 93 590306 Solenoid 93 591805 Inlet elbow 93 591804 Removable side section grey 93 593593 Removable side sec...

Страница 11: ...Diagram 13a Accessories for White Models 11 Diagram 13b Accessories for Chrome Models ...

Страница 12: ...to 12 months We DO NOT recommend these products be used in heavy or unsupervised commercial applications f For the service work to be undertaken free of charge the work must only be undertaken by Redring Xpelair Group Limited or our approved agents g Service under guarantee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends...