Schematic Diagram

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Fixing the unit to the wall 

 

 

Suitable screws and washers must be used through the designated keyholes on the backplate of 
the unit ensuring the unit securely fastened to the wall.

 

 

 

Ensure the fixing screws are horizontal and the unit, when installed, is level. 

 

Connecting the water supply and vent pipes 

 

 

When the unit is fixed to the wall, make the final water supply and steam vent connections and 
secure the pipework. 

 

 

Switch the water supply back on. 

 

Connecting the mains cable 

 

 

Ensure the mains supply is isolated. 

 

 

Connect the mains cable from the unit to the means for disconnection (eg. 13A fused double pole 
isolating switch).   

  

 

Ensure the cable clamps are firmly secured and the cable ends are tightened into the terminal 
block. 

 

Note:                                                                                                                                                                   
The supply cable must be a minimum of 1.0mm² 3-Core multi-strand PVC insulated mains 
cable. The terminal block will not accept cable diameters above 1.5mm².                                                            
Check that the mains supply matches the electrical rating on the product.                                                 
The rating plate is located on the bottom edge of the unit. 

 

IMPORTANT:                                                                                                                                               
Connect the supply cable, complying with BS.6500, to this appliance in accordance with the 
following code: 
GREEN AND YELLOW (EARTH) connect to the terminal marked “        ” . 
BLUE (NEUTRAL) connect to terminal marked “N”. 
BROWN (LIVE) connect to terminal marked “L”. 

 

WARNING: THIS APPLIANCE, AND ALL METAL PIPEWORK CONNECTED TO IT,                              

MUST BE EARTHED. 

 
 
 
 
 

Replacing the front cover  

 

 

Support the front cover and re-attach the neon light carefully clipping to the unit. 

 

 

Replace the front cover and secure using the top and bottom screws. 

 

 

Apply Teflon tape to tap thread and screw-in. 

 

 

Reconnect the mains water supply. 

 

 

Check for any leaks and make good prior to turning mains electricity supply on. 

 

 
 
 
 
 
 
 
 

Содержание Professional SB

Страница 1: ...9JJ UK Telephone 44 0 844 372 7761 Fax 44 0 84 372 7762 Website www applied energy com Technical Advisory Service Hotline 44 0 844 372 7766 THE BOILING WATER DISPENSER INSTALLATION OPERATING INSTRUCTIONS IMPORTANT This booklet should be left with the user after installation and demonstration ...

Страница 2: ...13A plug however this product is not to be classed as a portable appliance and as detailed on page 3 it is instructed that the unit is to be wired to a means for disconnecting the fixed wiring in all poles in accordance with the wiring rules eg 13A fused double pole isolating switch In the unlikely event that the unit is fitted incorrectly the recommendation is if test is carried out with water in...

Страница 3: ...urrent BS 7671 IEE Wiring Regulations and the Water Fittings Regulations Local regulations may apply in other countries The steam vent connection MUST BE MADE as required in these instructions A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules Check that the mains supply matches the electrical rating on the product The rating plate i...

Страница 4: ... top edge of the unit Disconnect the neon light carefully unclipping it from the front cover 9 Maintenance Descaling Process To Drain the unit Turn off the water and electricity power supplies Turn on the tap on the front of the unit to drain the tank Unscrew and remove the tap and remove 4 fixing screws on outer cover Shield the electronic controller from possible water damage Carefully remove th...

Страница 5: ... a MANUAL RESET SAFETY DEVICE which operates in a BOIL DRY situation and a MANUAL RESET THERMOSTAT for detecting excessive steam in the event of electronic controller failure or water solenoid valve failure Unless you are a qualified engineer DO NOT ATTEMPT to repair this unit yourself In the event of malfunction please contact our Technical Service Helpline on 0844 372 7766 WARNING SCALDING HOT W...

Страница 6: ...The supply cable must be a minimum of 1 0mm 3 Core multi strand PVC insulated mains cable The terminal block will not accept cable diameters above 1 5mm Check that the mains supply matches the electrical rating on the product The rating plate is located on the bottom edge of the unit IMPORTANT Connect the supply cable complying with BS 6500 to this appliance in accordance with the following code G...

Отзывы: