background image

 

 

THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 

YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, 

SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE 

AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION 

 OR INSTRUCTION CONCERNING USE OF THE APPLIANCE  

IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. 

 

CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. 

 

CLEANING AND USER MAINTENANCE SHALL NOT 

 BE MADE BY CHILDREN. 

 

 

Your 

Powerstream-Eco

 has been designed for convenience, economy 

and safety of use, provided that it is installed, used and maintained in 
good working order and in accordance with our instructions and 
recommendations. 

 

 

All wiring and installation must be supervised by a suitably 
qualified person. 

 

 

THIS APPLIANCE MUST BE EARTHED. 

 

 

The installation must be in accordance with the current edition of 

BS.7671 (

the “IEE Wiring

 

Regulations”)

 and “Part P” of the 

“Building 

Regulations”

 in force at the time of installation.  Installations outside 

England and Wales must also conform to any local regulations in effect. 

 

 

This appliance is intended to be permanently connected to the fixed 
electrical wiring of the mains supply with its own dedicated supply. 

 

 

Ensure that the mains water supply meets the requirements listed.  

 

 

This appliance must 

NOT

 be fitted where it may be subjected to freezing 

conditions.  

DO NOT

 switch the appliance on if you suspect it of being 

frozen.  Wait until you are sure it has thawed out. 

 

 

The unit MUST NOT be mounted upside down (diagram 1b).   

 

 

 

The unit MUST NOT be fitted to any type of THERMOSTATIC 

mixer valve or tap.  

 

 

If a non-return valve is fitted in the Inlet feed to the unit, then the 

installation should also include a 3.5 BAR Pressure Reducing Valve and a 
6 BAR Pressure Relief (Expansion) Valve. 

 

 

Isolate the mains electrical and water supply before removing 

the front cover of the appliance. 

IMPORTANT SAFETY INFORMATION 

Содержание 10.8kW Powerstream-Eco

Страница 1: ... after installation and demonstration It should be kept in a safe place as you may need to refer to it for general instructions or future maintenance REDRING POWERSTREAM ECO UNVENTED INSTANTANEOUS WATER HEATER Installation and User Guide Powerstream Eco ...

Страница 2: ...ail us on Service request redringxpelair com Remember to quote the exact type of unit as written on the front of the unit and on this leaflet The model and serial number are located on the bottom face of the unit Make a note of those numbers here and be sure to quote them if you call for advice Model Number _ _ _ _ _ _ _ _ _ _ _ Serial Number _ _ _ _ _ _ _ _ _ _ _ _ Note You may be charged for a s...

Страница 3: ... Wiring Regulations and Part P of the Building Regulations in force at the time of installation Installations outside England and Wales must also conform to any local regulations in effect This appliance is intended to be permanently connected to the fixed electrical wiring of the mains supply with its own dedicated supply Ensure that the mains water supply meets the requirements listed This appli...

Страница 4: ...ct flow rate tables on page 14 The unit MUST NOT be mounted upside down diagram 1b BEFORE YOU START Check that the mains electric is capable of supplying the required current See the rating plate for current requirements Check the pressure of the main water supply To operate correctly the unit requires the following running pressures Check the rating plate to see which applies Model Dynamic Water ...

Страница 5: ...it either above or below the basin Deciding the wiring route You have a choice of whether to feed the electric cable through the side or through the back of the unit If it going through the side of the unit cut out the plastic lug to expose the grommet diagram 2 If is going through the back of the unit cut through the grommet on the backplate with a sharp knife Take Care Make sure you do not remov...

Страница 6: ...VALVE AND A 6 BAR PRESSURE RELIEF EXPANSION VALVE WARNING ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS LISTED ON PAGE 4 BEFORE CONTINUING WITH INSTALLATION WARNING BEFORE CONNECTING THE PIPE WORK TO THE POWERSTREAM ECO ENSURE THAT THE PIPE WORK IS FULLY FLUSHED OUT Diagram 4a Plumbing with Non Return Valve Diagram 4b Unit serving Basin and shower ...

Страница 7: ...connections The unit comes with a service valve diagram 5 which should be fitted on the inlet of the unit Models have either Ø15mm straight shanks or NPT connections Check to see which applies The valve can be used to turn off the water supply to the unit if it needs servicing or to reduce the main supply flow if it is too high see Powerstream Eco commissioning section on page 9 Fitting the attach...

Страница 8: ...e In all cases the outer sheath of the cable MUST project through the grommet diagram 6 if side entry is used This will prevent water getting into the unit Strip back the insulation on the LIVE brown or red and NEUTRAL blue or black mains wires about 8mm Strip back any insulation on the EARTH green yellow or green about 20mm Feed the cable through the side or rear entry grommets as appropriate Con...

Страница 9: ...set to High see adjusting power level below Turn the service valve clockwise until the neon light goes out then turn it back until the neon just comes on check the water temperature at the handset and if necessary turn the cold tap on and adjust to get the desired shower temperature ADJUSTING POWER LEVEL The Powerstream Eco has four power levels shown in table below selected by rotating the centra...

Страница 10: ...u DO NOT enter the water flow during this time WARNING YOU MAY INITIALLY GET A SHORT BURST OF VERY HOT WATER FROM THE UNIT Turn on the cold or temperature tap if necessary to adjust the temperature of the water Make sure that no other outlets connected to the unit are used whilst you are in the shower or the water flow will drop suddenly When you have finished do not switch off the power if you ar...

Страница 11: ...LEAN THE SHOWER HANDSET REGULARLY All water contains particles of lime scale which build up in the shower handset and unit reducing the performance It is therefore important to clean the shower handset by simply rubbing the rubber nozzles or soaking in proprietary lime scale remover and rinsing thoroughly before use The frequency of this will depend on water hardness and experience Diagram 9 Mixer...

Страница 12: ... select to High For a shower adjust the spray pattern available on the multi mode handset Rotate power selector to Higher setting Water flow too low or temperature too high The main water supply is too low The hot tap is not fully open Power selector set too high Increase the supply water flow Make sure that the service valve is correctly adjusted Adjust the service valve so that the water is at t...

Страница 13: ...nect the main supply to the INLET marked in blue Use a pump to boost the supply from a storage tank Reset it by opening the unit and pushing the button on the cut out diagram 10 Before you do this you must remove the cause of the problem Contact Redring see page 2 Water too cold neon light on The power select is set too low One element is not working The Power Supply Voltage has dropped Change the...

Страница 14: ...0 6 0 Power level High Eco Low High Eco Low High Eco Low Summer temp C 58 41 37 51 37 34 46 34 31 Winter temp C 43 26 22 36 22 19 31 19 16 The unit includes a dual thermal cut out diagram 10 which is attached to the heat exchanger tube It will switch off the heater elements if the water flow is reduced too much and the temperature goes above a set limit The first stage cut out is cyclic and will a...

Страница 15: ... out manual reset 93 793789 Printed front cover complete 93 794403 Control knob 93 794404 Screw cover set 93 794405 Flow switch assembly 93 794406 Heat exchanger 9 5kW 240V 93 794407 Heat exchanger 10 8kW 240V 93 794408 Power selector Assembly 93 794409 For further details including a comprehensive list off accessories and spare parts Contact Redring After Sales Service see page 2 ADDITIONAL ACCES...

Страница 16: ...arts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation improper use or lack of maintenance including the build up of limescale The unit MUST NOT be fitted to any type of thermostatic mixer valve or tap The unit MUST NOT be fitted to a bath or kitchen sink other than for hand washing purpose...

Отзывы: