Install CUB5V- A
Drawing No. LP1137
Effective 07/2020
Model CUB
®
5V - Miniature Electronic
5-Digit DC Voltmeter
Installation Guide
1
See the Red Lion website at www.redlion.net for full user manual.
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
ORDERING INFORMATION
PART NUMBER DESCRIPTION
TYPE
CUB5VR00
DC Volt Meter with reflective display
CUB5
CUB5VB00
DC Volt Meter with backlight display
CUB5RLY0
Single Relay Option Card
Optional
Plug-in
Cards
CUB5SNK0
Dual Sinking Open Collector Output card
CUB5COM1
RS485 Serial Communications Card
CUB5COM2
RS232 Serial Communications Card
CUB5USB0
USB Programming Card
SPECIFICATIONS
1.
POWER
: Input voltage range is +9 to +28 VDC with short
circuit and input polarity protection. Must use an RLC model
MLPS or an NEC Class 2 or Limited Power Source (LPS) rated
power supply.
MODEL NO.
DISPLAY COLOR
INPUT CURRENT
@ 9 VDC
WITHOUT
CUB5RLY0
INPUT
CURRENT @
9 VDC WITH
CUB5RLY0
CUB5VR00
---
10 mA
40 mA
CUB5VB00
Red (max intensity)
85 mA
115 mA
CUB5VB00
Green (max intensity)
95 mA
125 mA
2.
DISPLAY:
5 digit LCD 0.48" (12.2 mm) high digits
CUB5VR00: Reflective LCD with full viewing angle
CUB5VB00: Transmissive LCD with selectable red or green
LED backlight, viewing angle optimized. Display color change
capability with output state when using an output module.
3. INPUT RANGES:
Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V
4. RESPONSE TIME:
Display: 500 msec min.
Output: 800 msec max (with input filter setting of 0)
5. USER INPUT (USR):
Programmable input. Connect terminal
to common (USR COMM) to activate function. Internal 10K
Ω
pull-up resistor to +9 to 28 VDC.
6.
ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5VR00: -35 to 75°C
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION:
Risk of electric shock.
C
C
US LISTED
US LISTED
UL
R
IND. CONT. EQ.
E137808
.13 (3.3)
(43.4)
1.71
2.95 (74.9)
SEL
.15 (3.8)
1.54 (39.1)
RST
(68 )
+.025
-.000
+8
-0
1.29 (32.8)
2.68
-.000
1.30
(33 )
-0
+6
+.024
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.