2
TURBO/HIGH PRESSURE
1. Power/Mode Selection Toggle Switch
Toggle left for Turbo/High Pressure,
Toggle right for Low Pressure EVAP
2. Turbo Testing Indicator
Indicates Turbo / High Pressure testing selected
3. Flow Meter
Measures flow rate into system under test
4. System Pressure Gauge
Displays the back pressure of system under test
5. Power Indicator
Green light indicates proper connection to
electrical power
6. Flow Control Valve (Variable)
Releases vapor / pressure into the system
Close flow control valve to lock out system for
pressure decay testing
7. Test Pressure Gauge
Indicates test pressure set by regulator
8. Vapor Test Switch
Begins ten-minute vapor cycle. Red light indicates
vapor cycle. Push again to stop testing
9. Air Only Test Switch
Begins ten-minute air only cycle. Blue light
indicates air only cycle. Push again to stop testing
10. Reset Switch
Clears stored logic
11. Adjustable Pressure Regulator
Adjust test pressure from 2-17 PSI (.14 - 1 BAR)
FRONT VIEW
1
5
2
9
8
10
11
7
3
6
4