background image

RDL-3100-RMJ 

PRODUCT  MANUAL

 

70-00184-05-00 

Proprietary Redline Communications © 2017

 

Page 

23

 of 25 

February 17, 2017 

(2)  This  device  must  accept  any  interference  received,  including  interference  that 
may cause undesired operation. 

5. 

FCC Information to Users @ FCC 15.21: 

Warning:  Changes  or  modifications  not  expressly  approved  by  Redline 
Communications cou

ld void the user’s authority to operate the equipment. 

5.1.2  ISED Notices 

Deployment in Canada 

This Class B Digital apparatus meets all the requirements of the Canadian Interference-
Causing Equipment. 

The  following  notices  about  deployment  in  Canada  are  included  in  training  and 
documentation provided to professional installers and operators of the final product: 

1. 

The final product must be professionally installed. 

2. 

WARNING -- ISED RF Exposure Warnings 

To satisfy ISED RF exposure requirements for RF transmitting devices, the following 
distances should be maintained between the antenna of this device and persons 
during device operation: 

Table 49: ISED: RDL-3100-RMA Recommended Safe Distances 

Frequency (MHz) 

Deployment

 

Separation Distance

 

4900 

PMP/PTP 

220 cm (86.6") or more 

5800 

PMP 

20 cm (7.9") or more 

5800 

PTP 

220 cm (86.6") or more 

To ensure compliance, operation at closer than these distances is not 
recommended. The antenna used for this transmitter must not be collocated in 
conjunction with any other antenna or transmitter. 

The RDL-3100-RMA has been designed to operate with an antenna having a maximum 
gain  of  32  dBi.  Antenna  having  a  higher  gain  is  strictly  prohibited  per  regulations  of 
ISED. The required antenna impedance is 50 ohms. 

This device has been designed to ensure that radio frequency emissions are maintained 
within the band of operation under all normal operating conditions listed in this manual. 

This device complies with ISED license-exempt RSS standard(s). Operation is subject to 
the following two conditions: 

1. 

This device may not cause interference, and  

2. 

This  device  must  accept  any  interference,  including  interference  that  may  cause 
undesired operation of the device. 

To  reduce  potential  radio  interference  to  other  users,  the  antenna  type  and  its  gain 
should be so chosen that the equivalent isotropic radiated power (EIRP) is not more than 
that required for successful communication. 

Déploiement aux le Canada 

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 

Les avis suivants à propos du déploiement au Canada sont inclus dans la formation et la 
documentation  fournies  aux  installateurs  professionnels  et  les  opérateurs  du  produit 
final: 

1. 

Le produit final doit être installé par un professionnel. 

2. 

AVERTISSEMENT - ISED avertissements d'exposition RF 

Содержание RDL-3100 series

Страница 1: ...ns 2017 Page 1 of 25 February 17 2017 RDL 3100 Family Broadband Wireless Systems RDL 3100 RMA Radio Modules Product Manual 1 Product Overview 6 2 Conditions of Use 7 3 Module Installation and Service 8 4 Final Product Requirements 11 5 Regulatory Notices 22 ...

Страница 2: ...rdlcom com Support support rdlcom com Training training rdlcom com Document Control 70 00184 05 00 RDL 3100 RMA_Module_Product_Manual 20170215a doc Disclaimer The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Additionally Redline makes no representations or warranties eith...

Страница 3: ...8 3 1 Installation into a Final Product 8 3 2 Module Servicing 9 3 3 Professional Installation 10 3 4 Safety Precautions 10 3 5 Radio Frequency Safety 10 4 Final Product Requirements 11 4 1 Frequency Bands 11 4 1 1 Antenna Use and Transmit Power 11 4 1 2 Certified Antennas 11 4 1 3 Power EIRP MIMO Operation 12 4 9 GHz FCC 47 CFR Part 90 Subpart Y and RSS III 12 5 2 GHz FCC 47 CFR Part 15 Subpart E...

Страница 4: ... 5 8 GHz output power 40 MHz channel PMP 24 dBi antenna 16 Table 23 FCC 5 8 GHz output power 40 MHz channel PMP 32 dBi antenna 16 Table 24 ISED 5 8 GHz output power 10 MHz channel PMP 10 dBi antenna 16 Table 25 ISED 5 8 GHz output power 10 MHz channel PMP 24 dBi antenna 16 Table 26 ISED 5 8 GHz output power 10 MHz channel PMP 32 dBi antenna 17 Table 27 ISED 5 8 GHz output power 20 MHz channel PMP ...

Страница 5: ... 2017 Page 5 of 25 February 17 2017 Table 47 ISED 5 8 GHz output power 40 MHz channel PTP 32 dBi antenna 21 Table 48 FCC RDL 3100 RMA Recommended Safe Distances 22 Table 49 ISED RDL 3100 RMA Recommended Safe Distances 23 Table 50 ISED RDL 3100 RMA distances de sécurité recommandées 24 ...

Страница 6: ...s sold as one component of a packaged system which includes a suitable housing for the module connectors for required external components including a power supply and antenna system This is afterwards referred to as the final product The final product may be designed and manufactured by Redline or a licensed third party Frequency settings within the specified frequency ranges are software keyed to...

Страница 7: ... unique to each module and must be installed and activated before the radio will operate The key contains sufficient security features that the professional installer and operator can not decode modify substitute or otherwise circumvent the operational restrictions imposed by the key The software key limits the transmit power operating frequency range and channel bandwidth per the regulator domain...

Страница 8: ...lation and Service 3 1 Installation into a Final Product The module must be installed only by trained professional technicians authorized by Redline or its agents The module must be installed only into an approved enclosure see Conditions of Use and only at an approved manufacturing facility or service depot Redline shall retain complete control over the final installation of the module and will e...

Страница 9: ...n of operation The software key must limit the mode of operation as a master or client The client mode is passive listener and while in this mode the module can not initiate any transmission without first receiving and decoding a valid authorization message from the master A module with a key for client operation can not be changed by the installer to enable master mode operation Redline will revi...

Страница 10: ...f RF equipment The installation and or service must be done using procedures designed to minimize any danger to technical personnel or any other person 3 5 Radio Frequency Safety The installer of this radio equipment must ensure the antenna is located or pointed such that it does not emit RF fields in excess of the general population limits as defined by FCC CFR 47 Part 2 1091 http www gpo gov fds...

Страница 11: ...t Power The module supports operation with 2 x 2 MIMO antenna systems with two transmit chains and two receive chains The module must be used only with certified antennas and using the channel size and output power level specified by the FCC ISED regulations 4 1 2 Certified Antennas This device has been designed to operate with the antennas listed in the following table Any additional antennas wil...

Страница 12: ... 70 2 26 BPSK 4965 0 19 96 18 79 22 42 24 70 2 28 4985 0 19 14 19 74 22 46 24 70 2 24 4945 0 20 14 18 65 22 47 24 70 2 23 256 QAM 4965 0 19 92 18 82 22 42 24 70 2 28 4985 0 19 08 19 75 22 44 24 70 2 26 Table 4 FCC 4 9 GHz output power 20 MHz channel 10 dBi and 24 dBi antennas Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB...

Страница 13: ...z output power 10 MHz channel PMP 32 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5160 0 3 11 3 13 0 11 4 70 4 81 BPSK 5200 0 3 01 3 55 0 26 4 70 4 96 5245 0 3 90 3 02 0 43 4 70 5 13 5160 0 3 22 3 44 0 32 4 70 5 02 256 QAM 5200 0 3 37 3 48 0 41 4 70 5 11 5245 0 3 89 3 28 0 56 4 70 5 26 Table 9 FCC 5 2 GHz ou...

Страница 14: ...Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5170 0 9 04 8 93 12 00 12 70 0 70 BPSK 5200 0 9 02 8 91 11 98 12 70 0 72 5230 0 8 95 8 84 11 91 12 70 0 79 5170 0 8 84 8 76 11 81 12 70 0 89 256 QAM 5200 0 9 00 8 96 11 99 12 70 0 71 5230 0 8 96 9 00 11 99 12 70 0 71 Table 14 FCC 5 2 GHz output power 40 MHz channel PMP 32 dBi...

Страница 15: ...PMP 10 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5735 0 22 49 22 37 25 44 26 70 1 26 BPSK 5790 0 22 64 22 47 25 57 26 70 1 13 5840 0 22 29 22 34 25 33 26 70 1 37 5735 0 22 63 22 34 25 50 26 70 1 20 256 QAM 5790 0 22 57 22 50 25 55 26 70 1 15 5840 0 22 26 22 36 25 32 26 70 1 38 Table 19 FCC 5 8 GHz output ...

Страница 16: ... MHz channel PMP 32 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5745 0 0 78 0 60 3 70 4 70 1 00 BPSK 5790 0 1 07 1 17 4 13 4 70 0 57 5830 0 0 78 0 90 3 85 4 70 0 85 5745 0 0 83 0 57 3 71 4 70 0 99 256 QAM 5790 0 1 11 1 20 4 17 4 70 0 53 5830 0 0 75 0 91 3 84 4 70 0 86 Table 24 ISED 5 8 GHz output power 10 M...

Страница 17: ... channel PMP 24 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5735 0 3 80 3 22 6 53 12 70 6 17 BPSK 5790 0 9 36 8 40 11 92 12 70 0 78 5840 0 3 14 3 31 6 24 12 70 6 46 5735 0 3 78 3 18 6 50 12 70 6 20 256 QAM 5790 0 9 25 8 41 11 86 12 70 0 84 5840 0 3 11 3 30 6 22 12 70 6 48 Table 29 ISED 5 8 GHz output power ...

Страница 18: ...Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5730 0 22 38 22 27 25 34 30 00 4 66 BPSK 5790 0 22 30 22 44 25 38 30 00 4 62 5845 0 21 97 22 21 25 10 30 00 4 90 5730 0 22 27 22 24 25 27 30 00 4 73 256 QAM 5790 0 22 37 22 40 25 40 30 00 4 60 5845 0 22 07 22 26 25 18 30 00 4 82 Table 34 FCC 5 8 GHz output power 10 MHz channe...

Страница 19: ...el PTP 32 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5745 0 15 95 15 81 18 89 30 00 11 11 BPSK 5790 0 21 90 21 84 24 88 30 00 5 12 5830 0 15 79 16 01 18 91 30 00 11 09 5745 0 15 90 15 84 18 88 30 00 11 12 256 QAM 5790 0 21 63 21 80 24 73 30 00 5 27 5830 0 15 74 16 11 18 94 30 00 11 06 Table 39 ISED 5 8 GHz...

Страница 20: ...annel PTP 24 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5735 0 3 80 3 22 6 53 30 00 23 47 BPSK 5790 0 22 64 22 47 25 57 30 00 4 43 5840 0 3 14 3 31 6 24 30 00 23 76 5735 0 3 78 3 18 6 50 30 00 23 50 256 QAM 5790 0 22 57 22 50 25 55 30 00 4 45 5840 0 3 11 3 30 6 22 30 00 23 78 Table 44 ISED 5 8 GHz output p...

Страница 21: ...5 68 30 00 4 32 5830 0 4 23 3 46 6 87 30 00 23 13 5745 0 4 48 3 41 6 99 30 00 23 01 256 QAM 5790 0 22 64 22 74 25 70 30 00 4 30 5830 0 4 24 3 44 6 87 30 00 23 13 Table 47 ISED 5 8 GHz output power 40 MHz channel PTP 32 dBi antenna Modulation Frequency MHz Power at ch0 dBm Power at ch1 dBm Combined output power dBm Output power limit dBm Power margin dB 5745 0 3 66 3 86 0 75 30 00 30 75 BPSK 5790 0...

Страница 22: ... for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guara...

Страница 23: ...hese distances is not recommended The antenna used for this transmitter must not be collocated in conjunction with any other antenna or transmitter The RDL 3100 RMA has been designed to operate with an antenna having a maximum gain of 32 dBi Antenna having a higher gain is strictly prohibited per regulations of ISED The required antenna impedance is 50 ohms This device has been designed to ensure ...

Страница 24: ...t strictement interdite par les règlements d Industrie Canada L impédance d antenne requise est de 50 ohms Ce dispositif a été conçu pour veiller à ce que les émissions de radiofréquences sont maintenus dans la bande de fonctionnement dans toutes les conditions normales de fonctionnement figurant dans ce manuel Cet appareil est conforme la norme d Industrie Canada exempts de licence RSS s Son fonc...

Страница 25: ...RDL 3100 M2M Solutions 70 00184 05 00 Proprietary Redline Communications 2017 Page 25 of 25 February 17 2017 302 Town Centre Markham Ontario Canada L3R 0E8 www rdlcom com ...

Отзывы: