background image

www.sureheat.com

27

200305-01C

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these acces-

sories, contact SHM International, Corp. at 1-800-229-5647 for information.

EQUIPMENT SHUTOFF VALVE

RMH-120-00088

 For all models. Equipment shutoff valve 

with 1/8” NPT tap.

SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply might be low (propane/LP units only)
You may feel your gas pressure is too low. If so, contact your local gas supplier.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts 

replaced under warranty.

PARTS UNDER WARRANTY 

Call  Customer  Service  toll  free  at

 

1-800-229-5647  to  order  parts  under  war-

ranty.
When calling Customer Service or your dealer, 

have ready:
•  Your name

•  Your address

•  Model and serial number of your heater

•  How heater was malfunctioning

•  Type of gas used (Propane/LP or Natural 

gas/NG)

•  Purchase date
Usually, we will ask you to return the defective 

part to the factory

PARTS NOT UNDER WARRANTY

Call  Customer  Service  toll  free  at

 

1-800-229-5647  to  order  parts  not  under 

warranty.
When calling Customer Service have ready:
•  Model number of your heater

•  The replacement part number

Содержание BWH30NLTE-2

Страница 1: ...ot touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Страница 2: ...s manual WARNING Improper installation adjustment al teration service or maintenance can cause injury or property damage Refer to this manual for correct in stallation and operational procedures For a...

Страница 3: ...er serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at hi...

Страница 4: ...off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately ca...

Страница 5: ...n either Propane LP or Natural gas The heater is shipped from the factory ready for connect ing to Propane LP The heater can easily be changed to Natural gas by having your quali fied installer follow...

Страница 6: ...UCT OF UNVENTED ROOM HEATERS Water vapor is a by product of gas combus tion An unvented room heater produces ap proximately one 1 ounce 30 mL of water for every 1 000 BTUs 0 3 KWs of gas input per hou...

Страница 7: ...eathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from...

Страница 8: ...to adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From O...

Страница 9: ...kerosene lamps etc in the air exist maycausewallstodiscolor Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial...

Страница 10: ...ounting bracket is located on back panel of heater It has been taped there for shipping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on...

Страница 11: ...ne up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Marking Screw...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks Figure 10 Mounting Heater Onto Mounti...

Страница 13: ...void gas leak age for the gas not being used at the inlet of regulator a qualified installer or service technician must use supplied cap You will notice a color coded plungerontheinsideoftheregu lator...

Страница 14: ...ile pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting Insta...

Страница 15: ...the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulator with wren...

Страница 16: ...lator with Vent Pointing Down Propane LP Supply Tank Equipment Shutoff Valve Ground Joint Union 3 8 NPT Pipe Nipple Tee Joint Reducer Bushing to 1 8 NPT 1 8 NPT Plug Tap Test Gauge Connection Sediment...

Страница 17: ...l leaks at once 6 Light heater see Lighting Instructions on page 18 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 19 8 Replace front panel 1 Open equi...

Страница 18: ...n above 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any air Then smell for gas including near the floor If yo...

Страница 19: ...ousing construction TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise to the OFF position Shutting Off Burner Only pilot stays lit Turn control knob clockwise to the PILOT p...

Страница 20: ...Code and for US instal lations the National Electrical Code ANSI NFPA NO 70 WARNING If repairing or replacing any electrical compo nent or wiring the original wire routing colorcodingandsecur ing loca...

Страница 21: ...to cool which shuts the heater off If pilot flame pattern is incorrect as shown in Figure 25 turn heater off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting pages 23 through 26 WARNING I...

Страница 22: ...es 2 Remove four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel us...

Страница 23: ...life and require no further lubrication However periodic cleaning vacuuming of the appliance around the air intake and exhaust as well as the fan heater is recommended For heavy or continuous use per...

Страница 24: ...valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page...

Страница 25: ...t 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 22 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold pressure is t...

Страница 26: ...products Heater produces un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page23 2 Gas leak See Warning State ment at the top of page 23 3 Low fuel sup...

Страница 27: ...ontact your local gas supplier REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Call Customer...

Страница 28: ...www sureheat com 200305 01C 28 PARTS MODEL BWH30NLTE 2 2 11 3 9 8 7 1 12 10 5 6 14 13 15 12 16 4 17...

Страница 29: ...161133 01 Piezo Ignitor 1 4 161130 01 Thermostat Valve Assy 1 5 Burner Assembly 1 6 161139 01 ODS Pilot 1 7 Dual Fuel Regulator 1 8 161200 01 Inlet Cover Plug 1 9 160960 01 Cap with Seal 1 10 Bezel T...

Страница 30: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Страница 31: ...____________________ ________________________________________________________________ ________________________________________________________________ _________________________________________________...

Страница 32: ...ge resulting from any of the following Negligent use or misuse of the product including exposing the product to chemicals or cleaning products not approved by SHM International Corp Corrosion rust or...