PREPARING FOR INSTALLATION
Before beginning assembly or operation of the
product, make sure all parts are present. Com-
pare parts with package contents list. If any
part is missing or damaged, do not attempt to
assemble, install or operate the product. Con-
tact customer service for replacement parts.
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied
to heater for shipping
Figure 1 - Vent-Free Gas Heater
Control Knob
Ignitor
Button
Front
Panel
Grill
Burner
Heater Cabinet
3. Check heater for any shipping damage. If
heater is damaged, promptly inform dealer
where you bought heater.
Water vapor is a by-product of gas combus-
tion. An unvented room heater produces ap-
proximately one (1) ounce (30 mL) of water for
every 1,000 BTUs (0.3 KWs) of gas input per
hour. Unvented room heaters are recommended
as supplemental heat (a room) rather than a
primary heat source (an entire house). In most
supplemental heat applications, the water vapor
does not create a problem. In most applications,
the water vapor enhances the low humidity
atmosphere experienced during cold weather.
The following steps will help ensure that water
vapor does not become a problem.
1. Be sure the heater is sized properly for the
application, including ample combustion
air and circulation air.
2. If high humidity is experienced, a dehu-
midifier may be used to help lower the
water vapor content of the air.
3. Do not use an unvented room heater as
the primary heat source.
WATER VAPOR: A BY-PRODUCT OF
UNVENTED ROOM HEATERS