Redback A 6514 Скачать руководство пользователя страница 3

Redback® A 6514

 Two Input Serial Volume Controller

www.altronics.com.au

Redback® Proudly Made In Australia

3

Redback® A 6514

 Two Input Serial Volume Controller

Figure 3 illustrates an example where the Redback

® 

A 6514 need to be controlled but also other devices require control 

from the Redback

®

 A 6500 wallplate. In this example the Redback

® 

A 6500 is connected to the Redback

®

 A 6505 via 

the Cat5e/6 cable which then passes through serial codes to the Redback

®

 A 6514 via the RS485-1 terminals or RS232-1 

terminals.
The Redback

® 

A 6505 can then control relays, the IR repeater and send serial codes out the second serial port to other 

equipment.

Fig 3.

Redback® A 6500

Redback® A 6505

24V DC PLUGPACK

(MINIMUM 1A)

(Cat5/6 Cable 50m Maximum)

A 1052 IR REPEATER

RELAY CONTROLLED

DEVICES

Relay OUT 
1      2      3

RS485-1

RS232-1

IR

RS485-2

RS232-2

TO A 6500

RS485

Redback® A 6514

240V AC @ 50Hz

Line

Mic 

L

R

100V

OUTPUT

+

2

1

3

Amplifier

RS232

DVD

REDBACK

DVD Player 1

RS 485

RS232-2

TO A 6500

INPUT 1LEFT

INPUT 1 RIGHT 

LEFT  OUT

RIGHT   OUT

INPUT 2 LEFT

INPUT 2 RIGHT   

DVD

REDBACK

DVD Player 2

Отзывы: