Low-Voltage Load 

Disconnect Isolator

SBI12-LLD

Содержание SBI12-LLD

Страница 1: ...Low Voltage Load Disconnect Isolator SBI12 LLD ...

Страница 2: ...belts pulleys and other parts that can cause injury to persons c Determine which post of the battery is grounded connected to the chassis If the negative post is grounded to the chassis as in most vehicles see e If the positive the post is grounded to the chassis see f d For use in negative grounded vehicles only Connect the POSITIVE RED terminals from the Battery Isolator to the POSITIVE POS P of...

Страница 3: ...als found on the front of the unit Ensure that connections are not accidentally bridged between terminals whilst tightening Connecting to the control terminals on the front of the SBI may cause damage to the unit and or equipment connected to it Connecting to the control terminals will void the warranty of the unit Do NOT connect to the control terminals SPECIFICATIONS System Voltage 12V Nominal T...

Страница 4: ... once the auxiliary battery has been overly discharged the Load Disconnect Isolator will turn off any connected loads Similarly if the battery climbs back above a suitable level the Load Disconnect Isolator will restore power to the connected loads RECOMMENDED FUSES CABLING Suitably sized Wire and fuses for the connected loads should be used REDARC recommend using MIDI fuses along with a quality f...

Страница 5: ... Load Disconnect Isolator force the loads to stay connected below the cutoff voltage hold the momentary push button and the Isolator will manually operate until the switch is released Care should be taken not to excessively discharge the Auxiliary battery Checking the Operation The SBI12 LLD should now be operational Once the auxiliary battery voltage rises to the ON voltage the SBI12 LLD will act...

Страница 6: ... Button for Override and LED LED NO RESISTOR REQUIRED Override Wire Override Wire Override Wire OPTION 1 OPTION 2 OPTION 3 5A Fuse 5A Fuse Override Wire BLUE Ground Wire BLACK Battery Terminal Load Terminal Ensure adequately sized cable is used Ensure the auxiliary battery and loads are properly grounded to a common chassis earth point Ensure the SBI12 LLD ground wire is making good contact with t...

Страница 7: ...should rise above 15 5 Volts the Smart Start will Disconnect to prevent the source of over voltage reaching the load Flash the LED 2 times for 20 seconds then reassess the fault condition continuing until the fault is cleared FAULT CODE 2 3 Flashes Voltage Drop Excessive Current Draw If the SBI12 LLD detects a voltage drop across its contacts of greater than 1 Volt for more than second then the un...

Страница 8: ...his Answer This can occur for one of two reasons Firstly switching an excessively large load which would drop the battery to below its lower voltage limit and causing the SBI12 LLD to turn off After turning off the load the battery would recover in voltage If the battery voltage climbs higher than the turn on threshold the SBI12 LLD would turn the loads back on Secondly voltage drop due to cable l...

Страница 9: ... the instructions of Redarc 9 If the Product is found to be working satisfactorily on return to Redarc or upon investigation by Redarc the Purchaser must pay Redarc s reasonable costs of testing and investigating the Product in addition to shipping and transportation charges Where Redarc is in possession of the Product the Product will be returned to the Purchaser on receipt of the amount charged ...

Страница 10: ...ectronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarc com au Mailing Address PO Box 469 Morphett Vale South Australia 5162 Copyright 2017 REDARC Electronics Pty Ltd All rights reserved www redarc com au WARSBI12LLD REV1 ...