STANDARD WIRING DIAGRAMS
5
Fuse
Auxiliary
Battery
Start
Battery
Fuse
Refer to the Battery Charger’s user manual for
appropriate power cable size reccomendations
Loads
Load
Fuse
SBI12-LLD
Standard Installation
Battery Charger
(LFPXXXX or BCDCXXXXD)
SBI with External LED
SBI with Push Button
for Override
Momentary
Pushbutton
Momentary
Pushbutton
LED
Resistor values:
12V = 1kΩ or 24V = 2.2kΩ
SBI with Push Button
for Override and LED
LED
NO RESISTOR REQUIRED.
Override
Wire
Override
Wire
Override
Wire
OPTION 1
OPTION 2
OPTION 3
5A
Fuse
5A
Fuse
Override
Wire
(BLUE)
Ground
Wire
(BLACK)
Battery
Terminal
Load
Terminal
• Ensure adequately sized cable is used.
• Ensure the auxiliary battery and loads
are properly grounded to a common
chassis earth point.
• Ensure the SBI12-LLD ground wire is
making good contact with the chassis
ground point.
• When using fuses make sure that the
fuse makes a good low resistance
connection.
• Fuse/Circuit Breaker ratings are
dependent on the type of installation
and the size of the loads.