30 | Care and Maintenance
Long-Term Storage
STORAGE ISOLATION SWITCH
The GoBlock has a Storage Isolation Switch that disconnects the internal battery from the unit
electronics. Note that it does NOT turn off the GoBlock inputs/outputs if there is another power
source connected.
When to use the Storage Isolation Switch:
It should be turned 'OFF' for long-term storage.
It must be turned 'OFF' for freighting/shipping of the GoBlock.
NOTE:
The Storage Isolation Switch is not intended for turning the GoBlock on/off during normal
use. Instead, turn the unit on/off via the Control Button
.
Rotate the Storage
Isolation Switch to 'OFF'
to isolate the internal
battery from the unit
electronics.
STORAGE BATTERY LEVEL
Do not fully charge or discharge the GoBlock prior to prolonged periods of storage. Ideally, the
GoBlock should be stored with a charge level between 40% and 70%.
The GoBlock has a discharge rate of 1 to 3% per month (Storage Isolation Switch 'OFF').
Topping up the charge level periodically may be required to maintain the charge level within the
recommended range.