2 INSTALLATION GUIDE
2.3.1 Input Wire Diameter Selection
REDARC recommends the installer use cabling and connections between 8B&S
and 6B&S automotive. REDARC recommends that the input wire be of the size
outlined in Table 2.3.1.
Distance from input vehicle
battery to The Manager30
Recommended Cross
Sectional Area (mm²)
Recommended
Diameter Equivalent
≤ 3m (10ft)
8
8 Gauge
> 3m (10ft)
10
6 Gauge
2.3.2 Output Wire Diameter Selection
REDARC recommends the installer use cabling and connections between 8B&S
and 6B&S automotive. REDARC recommends that the output wire be of the size
outlined in Table 2.3.2. For longer runs the use of at least 10mm
2
is recommended,
however this will lower efficiency by up to 3% (the recommended maximum
length is 5m/16 foot).
Distance (metres) from The
Manager30 to House battery
Recommended Cross
Sectional Area (mm²)
Recommended
Diameter Equivalent
≤1.5m (5ft)
8
8 Gauge
>1.5m (5ft)
10
6 Gauge
Figure 2.3.2 - Recommended output cable size
17
Figure 2.3.1 - Recommended input cable size
REDARC recommend using the SBI12-BLD
as the 12V relay for setting up the Load
Disconnect Feature for Non-Essential Loads.
Similarly, the SBI12-LLD is recommended
for use between the Auxiliary battery and the
Essential Loads in a Lithium Battery setup,
to protect the Lithium battery from excessive
discharge.
Содержание BMS1230S2-NA
Страница 1: ...Battery Management System BMS1230S2 NA THE MANAGER ...
Страница 37: ...4 REMOTE DRILL TEMPLATE 36 NOTE This template must be scaled at 100 for printing to remain accurate ...
Страница 38: ...37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 39: ...38 Two Year Product Warranty For warranty terms visit www redarcelectronics com ...