background image

Battery Management System

BMS1230S2-NA

TH

E

MANAGER

Содержание BMS1230S2-NA

Страница 1: ...Battery Management System BMS1230S2 NA THE MANAGER ...

Страница 2: ...C input cord may result in a risk of fire electric shock or injury to persons If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or service agent 5 Cable and fuse sizes are specified by various codes and standards which depend on the type of vehicle the Battery Charger is installed into Selecting the wrong cable or fuse size could result...

Страница 3: ...yes while working near a battery d If battery acid contacts your skin or clothing remove the affected clothing and wash the affected area of your skin immediately with soap and water If battery acid enters your eye immediately flood the eye with running cold water for at least 10 minutes and seek medical assistance immediately e To improve user safety it is recommended to control the charger and m...

Страница 4: ...g Instructions 11 1 Mounting the Main Unit 12 2 Mounting the Remote Monitor 13 3 Mounting the Battery Sensor 16 3 DC Cable Size Requirements 16 4 The Manager30 Wiring Connections 18 1 Load Disconnect Feature 18 2 Ignition Trigger Feature 18 3 Connecting the Battery Sensor 19 4 Wiring the Main Unit 19 5 Batteries 21 6 Fuses 22 7 MPPT Solar Regulator 22 3 USER Guide 23 1 Remote Monitor 23 2 Understa...

Страница 5: ...al to or below the output voltage 6 State of Charge SOC indication means you will always know how fully charged the battery is and how much longer it will need to achieve full charge An easy to operate high quality user friendly graphical display module lets you know what s going on at all times 7 The Manager30 is very reliable and includes reverse polarity protection without depending on fuses an...

Страница 6: ...cal system information while charging is in progress With the Remote Monitor you can customize how your house battery is charged and monitor where the charge is coming from keeping you in control at all times The Remote Monitor can be surface mounted on a wall or recessed into the dashboard of an RV for example 1 3 The Kit Includes Main Unit Battery Sensor Remote Monitor Output Connector T Piece R...

Страница 7: ...otection Yes Overload Protection Yes Max Volts Battery Terminals 25 C 77 F Nominal Storage Mode Touring Mode Float Gel Setting 14 4V 14 4V 13 5V AGM Setting 14 4V 14 4V 13 5V Calcium Setting 16 0V 15 2V 13 5V Standard Lead Acid Setting 15 5V 14 8V 13 5V Lithium Setting 14 5V 14 5V 13 6V Output Current Nominal 30A Thermal Specifications Operating Temperature 40 F to 176 F SLA AGM or Calcium Chargin...

Страница 8: ...UCTION 27 1 063 74 2 913 186 7 323 21 0 827 29 1 142 185 7 283 429 16 890 445 17 520 404 15 906 82 3 228 79 3 110 Figure 1 4 1 Main Unit Dimensions in mm inches Figure 1 4 2 Remote Monitor Dimensions in mm inches ...

Страница 9: ... monitored to detect only a limited number of faults such as short circuit over current and over voltage This allows The Manager30 to operate correctly even when loads are connected to the house battery This mode will always produce an output unless a fault condition is detected and will cycle through the three stages as required to maintain the house battery as outlined in Figure 1 4 1 Touring mo...

Страница 10: ...elow a predetermined threshold to ensure the battery stays charged Maintenance stage turns The Manager30 output off but continues to monitor the house battery and will revert to Float stage when necessary NOTE If The Manager30 is set to Storage mode and the vehicle is started The Manager30 will automatically switch to Touring mode once it senses an increase in input voltage from the alternator Whe...

Страница 11: ...tricted to the user setting Any excess current is used to power loads running from the battery under charge If no loads are running from the battery total current from The Manager30 will be restricted to the level set by the user 1 7 Recommended batteries Because of the rapidly changing nature of batteries and battery technology REDARC avoid recommending specific battery makes or models Instead we...

Страница 12: ...omponents of The Manager30 the Main Unit the Remote Monitor and the Battery Sensor Vehicle Battery Not Supplied House Battery Not Supplied BMS1230 Solar Panels Not Supplied Remote Monitor To Loads Not Supplied Battery Sensor 110VAC Mains Power DC DC Power Source Figure 2 1 1 System Layout Figure 2 2 1 The Manager30 System ...

Страница 13: ...ust be mounted to a flat solid support using 1 4 sized screws or bolts using all four mounting holes The Main Unit must be fixed using suitable screw mounts Failure to adequately mount the unit such as using adhesives to mount the unit will result in unreliable operation of the charger REDARC recommends that the Main Unit be mounted to optimize airflow past the heatsink Mounting the unit horizonta...

Страница 14: ... and 2 2 2 2 illustrate how to recess and wall mount the Remote Monitor unit Figure 2 2 2 3 illustrates removal of the Remote Monitor Recess Use the template provided Page 36 to mark the position and drill and cut the mounting holes into the wall Feed the Remote Monitor cable through the hole and connect it to the Remote Monitor Mount the Inner Assembly to the wall using 4 suitably sized screws Cl...

Страница 15: ...into the wall Attach the Back Plate to the wall using 4 suitably sized countersunk screws Clip the Inner Assembly into the Back Plate Clip the Front Face to the Inner Assembly Feed the Remote Monitor cable through the hole and connect it to the Remote Monitor Figure 2 2 2 2 How to wall mount the Remote Monitor 1 2 3 4 5 6 14 ...

Страница 16: ...fingers between the Front Face and the Inner Assembly in positions marked above and carefully pull back towards the front of the Remote Monitor Remove the Remote Monitor cable and the Inner Assembly is removed Insert a flat head screwdriver at a slight angle towards the front of the Remote Monitor and push back to depress the locking tabs 1 2 3 4 5 6 When the screwdriver is in a vertical position ...

Страница 17: ...e wrong cable or fuse size could result in harm to the installer or user and or damage to The Manager30 or other equipment installed in the system The installer is responsible for ensuring that the correct cable and fuse sizes are used when installing the Battery Charger The Manager30 is capable of drawing up to 50A from the Vehicle Battery which may be several feet from its installation location ...

Страница 18: ...put wire be of the size outlined inTable 2 3 2 For longer runs the use of at least 10mm2 is recommended however this will lower efficiency by up to 3 the recommended maximum length is 5m 16 foot Distance metres from The Manager30 to House battery Recommended Cross Sectional Area mm Recommended Diameter Equivalent 1 5m 5ft 8 8 Gauge 1 5m 5ft 10 6 Gauge Figure 2 3 2 Recommended output cable size 17 ...

Страница 19: ... Connector plug the connector into the Main Unit When disconnecting remove the Output Connector from the Main Unit first The DC Input should be disconnected next followed by the Ground chassis connection then the Battery Output connection 2 4 1 Load Disconnect Feature The Load Disconnect wire is a ground switch to activate a relay for disconnection of any loads running from the house battery The r...

Страница 20: ...s lead measures voltage and temperature at the battery 2 4 4 Wiring the Main Unit Refer to Figure 2 4 4 1 for required connections and to Figure 2 4 4 2 for a typical setup NOTE If a longer Remote Monitor cable is required a replacement CAT5 patch cable may be used up to a length of 10m The RJ12 adapter insert has been supplied to allow backwards compatibility with previous generation battery sens...

Страница 21: ...y Essential Loads Remote Monitor BMS1230 Mains AC from mains power rear side AC MAINS Non essential Loads House Battery 1 2 3 4 5 6 2 Battery Sensor 40A Fuse Not supplied Load Fuses Not supplied The size of this fuse relates to the total current draw of all the loads connected to the House Battery and should be rated slightly higher than this Essential loads are loads which must be left on at all ...

Страница 22: ...d 2 5 2 show standard wiring for batteries in series and parallel respectively To ensure that all batteries are equally charged loads and The Manager30 should be connected with ground and 12V power connected diagonally opposite across all batteries as shown in Figure 2 5 2 The Ah rating needs to be setup when prompted on first start up Refer section 3 3 these settings can also be modified in the A...

Страница 23: ...int Tracking MPPT algorithm on the solar input to ensure that the greatest charge possible is transferred from the solar panels to the battery under charge As conditions change the MPPT algorithm adjusts to maintain the optimum point at which the solar panels can deliver the most power An array of solar panels can be connected to The Manager30 solar input on the condition that the open circuit out...

Страница 24: ...Display The top left corner of the screen always displays the title of the present menu Use the Up and Down buttons to move between menus and to change settings such as battery type and contrast level At any time during operation the Home button will take you back to the Home Screen unless otherwise specified The Home Screen can be set to any of the top level User Menu screens described in section...

Страница 25: ... used not only for the clock screen but also on the Charge per Hour and Charge per Day log screens The Time and Date settings are not retained in memory so in the event that the charger loses ALL power sources Input and Output upon reconnection the unit will prompt the user to enter the Time and Date again The Clock screen is also the default Home Screen Set the Time Date N A Charging Status Scree...

Страница 26: ...ger30 uses the estimated State of Charge value to calculate based on the current into and out of the house battery the time to reach 100 State of Charge You may use this to decide when to disconnect AC power for example Similarly The Manager30 uses the estimated State of Charge value to calculate based on the current power usage of the system e g of loads such as fridges lighting the useful time r...

Страница 27: ...ut voltage level as well as percentage bar graph of input power provided Only two sources are used at any one time If a source is not detected a circle with a line diagonally through it will display indicated that the source is not present If the Solar andAC inputs are both in use and the DC input is detected the DC voltage will be displayed however the bar graph will display the not available sym...

Страница 28: ...The Manager30 uses to charge the battery so it is important to select the correct battery type Once you are happy with your selection move on to the Size of Battery screen The Size of Battery screen allows the user to indicate the battery bank size When you have chosen this value the menu will ask for confirmation of the settings while displaying them on the screen Refer section 2 5 for battery si...

Страница 29: ... 100 understood The Advanced Settings menu allow modification of settings relating to advanced operations of The Manager30 unit The Remote Settings menu allows modification of the settings listed below Edit Selected Setting Remote Settings Screen Cycle through Settings Cycle through Settings Each setting can be adjusted using the Up and Down controls Confirm Setting Adjustment Cancel Setting Adjus...

Страница 30: ...he alarm will sound The Alarm SOC can be set to from 0 100 The MaxCharge Current setting refers to the amount of current permitted by The Manager30 to charge the battery up to a maximum of 30 Amps Set Charging Current Screen Advanced Settings Screen R Bus Diagnostics Screen Low SOC Alarm Screen If the Charging Current setting is set lower than 30Amps the excess current will be used to supply the l...

Страница 31: ...Bus Diagnostics Screen The Disconnect Trigger setting can be set to Disconnect Loads OFF Connect Loads ON or to operate from either SOC or Voltage level triggers If either Voltage or SOC are selected at the Disconnect Trigger setting screen the Disconnect trigger level will need to be selected Once the Disconnect trigger level is selected the Reconnect trigger level must be selected Note that ther...

Страница 32: ...ngs for The Manager30 A list of the factory settings can be found on Page 34 Restore Settings Confirm N A Advanced Settings Screen About Screen If The Manager30 detects a problem with the charging system that does not prevent it from charging the battery it will alert you via a Warning screen and an alarm buzzer and continue charging The screen will give a brief description of the problem and allo...

Страница 33: ...sis Contact Details power redarcelectronics com www redarcelectronics com United States Canada Mexico 1 704 247 5150 1 604 260 5512 52 558 526 2898 32 If The Manager30 detects a problem with the charging system that prevents it from continuing to charge the battery it will alert you via a Fault screen and an alarm buzzer and will instantly terminate the charging cycle until the fault condition is ...

Страница 34: ...upplier DC supply over voltage The DC input voltage is too high over 32V Check DC input refer to specified input range Solar supply over voltage The solar input voltage is too high above 32V Check solar input refer to specified input range No battery sensor connected The supplied battery sensor is not connected or is faulty Connect battery sensor if faulty return to supplier Low battery State of C...

Страница 35: ...y 40AH Charge Mode TOURING Key Tone Status ON Contrast 50 Brightness 90 Backlight Timer 30 secs Home Screen Timer 30 secs Language English Max Charge Current 30 Amps Low SOC Alarm 10 Low Voltage Alarm 10 5 Volts Load Disconnect Off DC Input Trigger Auto Modification of the Advanced Settings menu items affect the way The Manager30 unit responds to charging situations Modification of these settings ...

Страница 36: ... solar panel voltage level to match the maximum power point In this situation solar will be selected as a source however little or no current will be flowing into the battery I have just finished wiring The Manager30 and when I turn the unit on the Remote Monitor says No Battery Sensor Detected is my unit faulty The Battery Sensor has a timeout function in built into the unit If the Battery Sensor...

Страница 37: ...4 REMOTE DRILL TEMPLATE 36 NOTE This template must be scaled at 100 for printing to remain accurate ...

Страница 38: ...37 THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 39: ...38 Two Year Product Warranty For warranty terms visit www redarcelectronics com ...

Страница 40: ...ada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe power redarcelectronics eu www redarcelectronics eu 44 0 20 3930 8109 Free technical assistance For product and technical support contact your regional distributor call our head office between 8 00am to 5 30pm Australian Central Standard Time Monday to Friday or send an email using the regional specific details outlined below For specific USA War...

Отзывы: