2 INSTALLATION
2.9 Fusing
REDARC recommend using MIDI style bolt down fuses as they
ensure a low resistance connection. The REDARC FK40 and FK60
fuse kits are recommended.
Blade type fuses are not recommended as they can result in a high
resistance connection which causes excess heat and may damage
the fuse holder and/or the wiring. Self-resetting circuit breakers are
not recommended as they may trip prematurely due to the heat
generated by the current fl owing through the wires.
3 TROUBLESHOOTING
Are all
battery negative wires,
solar negative wire and BLACK
BCDC wire connected to a
common ground point?
(chassis)
Is the input
voltage above the
required turn ON threshold?
(Refer to page 4)
Is the auxiliary
battery voltage
above 4v?
Check the connection
to the BCDC, and the
orientation of the LED as per
the install diagrams. If the problem
is still evident contact a qualified
Auto Electrician, or REDARC
Electronics.
The BCDC is operating correctly. If a low
auxiliary battery voltage occurs - check
BROWN wire is making a good
connection to the auxiliary battery. If the
problem is still evident, get a qualified
Auto Electrician to inspect the system.
The BCDC is not operating
correctly. Have a qualified
Auto Electrician check the wiring,
fuses, batteries and charging
system or contact REDARC
Electronics for more information.
Check the input.
If the problem is still evident
contact a qualified Auto
Electrician or REDARC
Electronics.
Remove all loads from the
auxiliary battery and charge it
overnight, using a multi-stage charger
and then recheck the battery.
If the battery voltage is
still low, replace battery.
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Start and run engine
for 30 seconds - leave
engine running whilst
troubleshooting.
Shutdown the
vehicle and rectify
the problem.
Is the
‘Charge Status’ light
flashing?
If an External LED
is fitted, is it working as
described on page 5
of this manual?
Check
the BLUE wire.
VEHICLE - BLUE to IGNITION
SOLAR - BLUE to GROUND or
NO CONNECT, is the BLUE
wire setup like
this?
Check the RED
wire. Is it installed with
appropriate gauge wire and
connected to the source
you require?
A single fuse and holder
setup from the Fuse Kits
available from REDARC.
Part number FK40 (40A)
or FK60 (60A).