RED SHIELD WS100G2 Скачать руководство пользователя страница 5

Sensor

Door/Window Sensor

Door/Window Sensor

Motion Sensor

Zone

1

2

8

Status (MODE)

ARM

ARM

ARM

A. Adjusting Exit Delay

The default setting of the Smart Panel allows the user 20 seconds to exit the property before the alarm is 
ARMED. However, this Exit Delay can be adjusted to between 10 and 60 seconds as follows:

B. Adjusting Entry Delay

The default setting of the Smart Panel allows the user 30 seconds to enter the property and DISARM the alarm 
before it is triggered. However, this Entry Delay can be adjusted to between 10 and 60 seconds as follows:

Keys

(1234/ 
4-digit PIN)
+

Description

Enter the default PIN “ 1 2
3 4 ” OR your new 4-digit 
PIN for setting followed by 

The Smart Panel will display the below image: 

Note

1

2

3

4

(1234/ 
4-digit PIN)
+

*To make sure you are in STANDBY mode: 
- Enter the default PIN “ 1 2 3 4 ” OR your new 4-digit PIN 
- Press  
- The Smart Panel will display the image below when you are 
in STANDBY mode: 

 
(One  beep  indicates  that  you  entered  a  valid  PIN,  three 
beeps indicate that an invalid operation was performed).

Press         to complete the
setting 

Keys

(1234/ 
4-digit PIN)
+

Description

Note

1

*To make sure you are in STANDBY mode: 
- Enter the default PIN “ 1 2 3 4 ”
 OR your new 4-digit PIN 
- Press         .
- The Smart Panel will display the below image while you were 
in STANDBY mode: 

 
(One  beep  indicates  that  you  entered  a  valid  PIN,  three 
beeps indicate that an invalid operation was performed).

- LCD display      flashes with “2”
- Re-enter the new 4-digit PIN
- Press         for final confirmation
(One beep indicates that you entered a valid PIN, two beeps
indicate that an invalid operation was performed).

5 New 4-digit

PIN +

Re-enter new PIN for 
followed by         for final 
confirmation

3.2 Transmitting an emergency (Panic) alarm 

3.2.1 Using the Panic alarm 

Pressing         &          buttons together on the Keypad or Key Fob Remote Control will immediately transmit an 
alarm signal to the Smart Panel, activating the siren, and transmitting an alarm signal to any optional response 

devices (Auto Dialer & Outdoor Bell Box), to request emergency assistance

To disarm the Panic alarm
On the Smart Panel: Enter your 4-digit PIN followed by         to exit from the Panic alarm. 
On the Key Fob Remote Control: Press         to exit from the Panic alarm.

3.2.2 Using the Panic alarm without activating the siren

If you are forced to disarm the system, enter the Duress Password to stop the siren from sounding. The Smart 
Panel will then silently transmit an alarm signal to the optional response devices (Auto Dialer & Outdoor Bell 

Box) to request emergency assistance.

Duress Password:
 

Enter the default 4-digit PIN +         (                                   +         ) +

 

OR 

 

Enter your personalised 4-digit PIN+         +

3.3 Operating different modes

 

The system has 4 operating modes (STANDBY, ARM, ALERT, and HOME) to suit individual requirements. 

These modes can be set as follows:. 

3.3.1 STANDBY mode

If in STANDBY mode, the Smart Panel is prepared for mode selection. 

You must be in STANDBY 
mode  before  turning  to 
ARM mode

3.3.2 ARM mode  

When in ARM mode, the Smart Panel siren will sound and the Smart Panel flashes RED every 1.5 seconds 
when the system is triggered.
ARM mode default setting: 

You must be in STANDBY 
mode before adjusting the 
Exit Delay

Press         then         (as 

many times as required) 

to set the new Exit Delay

- When         is pressed the first time the Smart Panel flashes 
with the number of seconds currently set for the Exit Delay 
(The factory default setting is 20 seconds)
- Each time        is pressed the Exit Delay is increased by a 
further 10 seconds between the adjustable range of 10 to 60 
seconds
- The Exit Delay time on the LCD display will flash until the 
setting is completed
Confirm the setting and return the Smart Panel to STANDBY 
by pressing

Keys

(1234/ 
4-digit PIN)
+

Description

Note

1

*To make sure you are in STANDBY mode: 
- Enter the default PIN “ 1 2 3 4 ” OR your new 4-digit PIN 
- Press  
- The Smart Panel will display the image below when you are 
in STANDBY mode: 

 

(One  beep  indicates  that  you  entered  a  valid  PIN,  three 
beeps indicate that an invalid operation was performed).

You must be in STANDBY 
mode before adjusting the 
Entry Delay

- 7 -

- 6 -

Содержание WS100G2

Страница 1: ...STANDBY mode 3 3 2 ARM mode A Adjusting Exit Delay B Adjusting Entry Delay C Adjusting the Alarm Duration D Muting the Audible Countdown E Arming the system F Disarming the system G Zone settings H T...

Страница 2: ...ntee 100 protection against burglary or environmental problems All alarm systems are subject to possible compromise or failure to warn for a variety of reasons Please note that you may encounter probl...

Страница 3: ...seconds with triggered zone indicated To stop enter 4 digit PIN and press HOME Zone triggered under ARM status 2 Zone triggered under ALERT status Sound output Chime ding dong Smart Panel flashes GRE...

Страница 4: ...mart Panel Fig 3 Replace the cover and screw and connect the AC adaptor to a wall socket Fig 4 Fig 2 WS 301 9V battery Fig 1 WS 301 Fig 3 WS 301 Fig 4 WS 301 Step 1 Description Note Insert 9V Alkaline...

Страница 5: ...rm signal to any optional response devices Auto Dialer Outdoor Bell Box to request emergency assistance To disarm the Panic alarm On the Smart Panel Enter your 4 digit PIN followed by to exit from the...

Страница 6: ...led a number will appear as displayed in the image below The system will then enter ARM mode after 15 seconds Press to complete the setting Keys 1234 4 digit PIN Description You must be in STANDBY mod...

Страница 7: ...ess on the remote control 4 Return to ARM mode after the initial triggering After the initial triggering the alarm will immediately sound without delay if any other sensors are triggered 3 3 3 ALERT m...

Страница 8: ...e Smart Panel is in STANDBY mode and then enter HOME mode by taking the following steps B Exiting the HOME mode On the Smart Panel Enter your 4 digit PIN followed by to exit HOME mode On the Key Fob R...

Страница 9: ...ll appear If the red light does not appear adjust the mounting angle accordingly Perform the walk test again after 3 minutes Repeat this procedure until motion is detected Whilst carrying out the test...

Страница 10: ...remotes enrolled after deletion One beep indicates that the remote was successfully deleted from the Smart Panel Press to complete the deletion iii Operating the Key Fob Remote Control The remote can...

Страница 11: ...rent location for better RF performance Q 4 How do I attach my Sensors A 4 Adhesive tape and screws are provided for the purpose of securely mounting these items Please refer to the user guide for mor...

Страница 12: ...rces of interference and to protect against faults 6 2 Specifications 6 2 1 Smart Panel Power source AC adaptor Back up power 9V alkaline battery x1pc Sensor numbers Unlimited House Code 4 Jumpers Sir...

Отзывы: