SECTION 6 – GENERAL INFORMATION

5.2 Troubleshooting 

AC power failure:

This may occur if your security system is accidentally unplugged or if there has been a mains power cut. If a 
full power failure occurs, please contact your electric company to find out the source of the problem. The 
back-up battery will continue to run the system for approximately 6 hours. 

System battery failure:

This may occur if the emergency back-up battery has been drained and needs to be replaced. If AC power is 
not restored, the low battery symbol will flash indicating that the Smart Panel back-up battery is running low. 
The back-up battery should be replaced once the low battery symbol appears.

Sensor failure:

This may occur if a sensor is not communicating with the Smart Panel. It is necessary for you to ensure the 
House Security Code dipswitch and jumpers of the sensors are set correctly to the Smart Panel. 

6.1 Product Information

 

Wireless systems are reliable and tested to high standards; however, it is important to consider that there are 
some limitations due to their transmitting power and range:
-   Receivers may be blocked by radio signals occurring on or near operating frequencies, regardless of the 
code selected.
-   A receiver can only respond to one transmitted signal at a time.
-   Wireless equipment should be tested regularly to determine whether there are sources of interference and 
to protect against faults.

6.2 Specifications

 

6.2.1 Smart Panel

 

Power source:      AC adaptor
Back up power:     9V alkaline battery x1pc
Sensor numbers: 

  

 

Unlimited

House Code:      4 Jumpers
Siren output:                                                               120dB (Duration-adjustable)

 

6.2.2 Key Fob Remote Control

Power source:      12V alkaline battery x 1pc
RF working transmission frequency:    

868.35MHz +/-0.5MHz

House Code:      4 Jumpers

6.2.3 Door/Window Sensor

Power source:      AAA alkaline battery 1.5V x 2pcs
RF working transmission frequency: 

  

868.35MHz +/-0.5MHz

House Code:      4 Jumpers 
Zone Code:  

   Pin header: 8 pin

6.2.4 Motion Sensor 

Power source:      9V alkaline battery x1pc
RF working transmission frequency: 

 

868.35MHz +/-0.5MHz

PIR detection angle:  

  <110 Degree (@9VDC)

PIR detection range: 

                                    “H”:< 15M “M”:< 6M “L”:< 4M 

House Code:      4 Jumpers 
Zone Code:  

   Pin header: 8 pin

Power saving timer: 

  3 minutes

6.3 Maintenance

The product may be cleaned with a soft damp cloth and then wiped dry.  Do not use abrasive, solvent based 
or aerosol cleaners as this may damage and/or discolour the product.  Do not allow water to enter or attempt 
to clean the inside of the unit.

6.4 Batteries

Do not allow batteries to corrode and leak as this may cause permanent damage to the product.
Take care to insert the batteries with the correct polarity as shown inside the battery compartments.
Do not mix new and old batteries or different types of batteries.
Do not fit rechargeable batteries.
At the end of their useful life the batteries should be disposed of via a suitable Recycling Centre. Do not 
dispose of with your normal household waste. DO NOT BURN.

- 21 -

- 20 -

Содержание WS100G2

Страница 1: ...STANDBY mode 3 3 2 ARM mode A Adjusting Exit Delay B Adjusting Entry Delay C Adjusting the Alarm Duration D Muting the Audible Countdown E Arming the system F Disarming the system G Zone settings H T...

Страница 2: ...ntee 100 protection against burglary or environmental problems All alarm systems are subject to possible compromise or failure to warn for a variety of reasons Please note that you may encounter probl...

Страница 3: ...seconds with triggered zone indicated To stop enter 4 digit PIN and press HOME Zone triggered under ARM status 2 Zone triggered under ALERT status Sound output Chime ding dong Smart Panel flashes GRE...

Страница 4: ...mart Panel Fig 3 Replace the cover and screw and connect the AC adaptor to a wall socket Fig 4 Fig 2 WS 301 9V battery Fig 1 WS 301 Fig 3 WS 301 Fig 4 WS 301 Step 1 Description Note Insert 9V Alkaline...

Страница 5: ...rm signal to any optional response devices Auto Dialer Outdoor Bell Box to request emergency assistance To disarm the Panic alarm On the Smart Panel Enter your 4 digit PIN followed by to exit from the...

Страница 6: ...led a number will appear as displayed in the image below The system will then enter ARM mode after 15 seconds Press to complete the setting Keys 1234 4 digit PIN Description You must be in STANDBY mod...

Страница 7: ...ess on the remote control 4 Return to ARM mode after the initial triggering After the initial triggering the alarm will immediately sound without delay if any other sensors are triggered 3 3 3 ALERT m...

Страница 8: ...e Smart Panel is in STANDBY mode and then enter HOME mode by taking the following steps B Exiting the HOME mode On the Smart Panel Enter your 4 digit PIN followed by to exit HOME mode On the Key Fob R...

Страница 9: ...ll appear If the red light does not appear adjust the mounting angle accordingly Perform the walk test again after 3 minutes Repeat this procedure until motion is detected Whilst carrying out the test...

Страница 10: ...remotes enrolled after deletion One beep indicates that the remote was successfully deleted from the Smart Panel Press to complete the deletion iii Operating the Key Fob Remote Control The remote can...

Страница 11: ...rent location for better RF performance Q 4 How do I attach my Sensors A 4 Adhesive tape and screws are provided for the purpose of securely mounting these items Please refer to the user guide for mor...

Страница 12: ...rces of interference and to protect against faults 6 2 Specifications 6 2 1 Smart Panel Power source AC adaptor Back up power 9V alkaline battery x1pc Sensor numbers Unlimited House Code 4 Jumpers Sir...

Отзывы: