red lion Yaskawa 2000 Скачать руководство пользователя страница 4

 

Y

ASKAWA 

SMC – S

ERIAL 

P

ORT AND 

TCP I

NFORMATION 

S

HEET FOR 

C

RIMSON V

2.0 

ACTION TYPE: 

1.  COMMAND – A new value written to these instructions will execute  

the command. 

2.  DATA R/W – Reads the current value and will send a new value. 
3.  READ DATA – Reads the current value. Ignores any write attempt. 
4.  COMMAND DATA – Reads data that is stored in HMI. Stores written data in 

HMI for retrieval when the related command is executed. E. g., the operator 
writes to CHA, CHB, and CHC. The HMI will store the data, and the values 
will be transmitted to the SMC only when the CH command is executed. 

5.  COMMAND/STATUS – Executes the command when a new value is written 

to it, reads the current status. 

6.  Send 0/1 to Axis – Executes the command on the selected Axis. 

7.  BIT WRITE – Clears the configured Output bit if the written data is 0, 

otherwise sets the bit. 

 
“Reading” any COMMAND will set the item to 0, except as described in  

Note 1, below. 
 
Note 1: HX and XQ are commands that accept a line number (<32767) as a data 

input. It is recommended that these two commands be selected with Access set 
to Read and Write, when declared as a variable. The driver will then set the 
value of these to –1, so that the command will be executed every time a valid 

line number is sent. 

 

User Variables 

 
User Variables YP through YY are selectable. If more are needed, it is possible to use 
one variable as an index, and another for the data. Use the data comparison functions of 
the software to route the data properly. For example, VariableArray[YY] = YX, will 
provide as many user variables as needed. 
 
In many cases, a clever programmer might be able to use higher bits of the transferred 
data word to indicate the source of the data in the lower bits. 
For example, VariableArray[(YY & 0xFF000000)>>24] = YY & 0x00FFFFFF, will 
allow 256 independent results of values less than hex 1000000 (decimal 16777216). 
 
In either case, use “On Update” to transfer the proper values to the proper locations. 
 

TCP Information

 

 
The G3 Ethernet Port must be manually configured to a fixed IP. When the Protocol is 
selected, the SMC must be configured to its internal IP. The programmer may use the 232 
port, with the IA command, to set that IP, code the IP in the SMC program, or use the 
Boot P utility of the Yterm software. 

 

Содержание Yaskawa 2000

Страница 1: ...eedback Send 0 to AXIS AFA Enable Analog Feedback Send 1 to AXIS AI After Input DATA R W AL Arm Latch COMMAND AM After Motion COMMAND AO Analog Output DATA R W AP After Absolute Postion DATA R W AR After Relative Distance DATA R W AS At Speed COMMAND AT At Time DATA R W BG Begin Motion COMMAND BL Reverse Software Limit DATA R W BN Burn COMMAND BP Burn Program COMMAND BV Burn Variables COMMAND CB C...

Страница 2: ...A Master Axis for Gearing COMMAND GR Gear Ratio DATA R W HM Home COMMAND HX Halt Task Execution COMMAND Note 1 IA Ethernet IP Address Not Available in TCP DATA R W IH Open Internet Handle COMMAND IHA Internet Handle Handle COMMAND DATA IHB Internet Handle IP COMMAND DATA IHC Internet Handle Port COMMAND DATA IHD Internet Handle Protocol COMMAND DATA IHE Internet Handle Terminate COMMAND IL Integra...

Страница 3: ...on READ DATA TS Tell Switches READ DATA TT Tell Torque READ DATA TV Tell Velocity READ DATA TW Timeout for In Position MC DATA R W VA Vector Acceleration DATA R W VD Vector Deceleration DATA R W VE Vector Sequence End READ DATA VR Vector Speed Ratio DATA R W VS Vector Speed DATA R W VT Vector Time Constant DATA R W WC Wait for Contour Data COMMAND WT Wait DATA R W PF Position Format DATA R W VF Va...

Страница 4: ...e two commands be selected with Access set to Read and Write when declared as a variable The driver will then set the value of these to 1 so that the command will be executed every time a valid line number is sent User Variables User Variables YP through YY are selectable If more are needed it is possible to use one variable as an index and another for the data Use the data comparison functions of...

Страница 5: ... V2 0 Cable Information G3 RS232 Port SMC 232 Port TxD 5 RxD 3 RxD 2 TxD 2 CTS 6 CTS OUT 4 RTS 1 CTS IN 1 0V 3 and or 4 5 For Multi Axis Control with an SMC as a Master that controls other SMC s the connection MUST be made as above or improper operation may occur ...