background image

4. 

ENVIRONMENTAL CONDITIONS:

Operating Temperature Range: 0 to 50°C
Storage Temperature Range: -20 to 80°C
Operating and Storage Humidity: 80% maximum relative humidity (non-

condensing) from 0 to 50°C.

Altitude: Up to 2000 meters.

5. 

CONSTRUCTION:

Installation Category I, Pollution Degree 2.

6. 

INSTALLATION REQUIREMENTS:

See “Installing the XCRS Option

card” for more details.

2

Figure 2

Figure 3

Figure 4

Figure 1

BLOCK DIAGRAM

INSTALLING THE XCRS OPTION CARD

1. Remove power from the unit
2. Insert a flat-bladed screwdriver into the slot at the top of the expansion port

cover. Gently apply pressure on the screwdriver in an upward direction until
the expansion port cover disengages from the unit as shown in Figure 1.  

3. Verify that the option card knobs are in the “unlocked” position as shown in

Figure 2.

4. Carefully insert the option card into the expansion port opening while

aligning the card-edge connector on the option card with the main board's
header, as shown in Figure 3. Once aligned, gently press on the front of the
card until it is flush with the front of the case.

5. Turn the option card knobs to the locked position as shown in Figure 4.

Caution:

The expansion and main circuit boards contain static

sensitive components. Before handling the cards, discharge static
charges from your body by touching a grounded bare metal object.
Ideally, handle the cards at a static controlled clean workstation.
Also, handle the cards by the edges only. Dirt, oil, or other
contaminants that may contact the cards can adversely affect circuit
operation.

Warning: Risk of Danger:

Be sure to remove all power before

removing the expansion port cover

Содержание XCRS

Страница 1: ...RMATION 1 Contact your Red Lion distributor or visit www redlion net for complete selection 2 Red Lion offers RJ modular jack adapters Refer to DR literature for complete details 3 Use these part numbers to purchase Crimson 2 0 on CD with a printed manual USB cable and RS 232 cable Otherwise download free of charge from www redlion net SPECIFICATIONS 1 POWER REQUIREMENTS Power is supplied to the o...

Страница 2: ...fy that the option card knobs are in the unlocked position as shown in Figure 2 4 Carefully insert the option card into the expansion port opening while aligning the card edge connector on the option card with the main board s header as shown in Figure 3 Once aligned gently press on the front of the card until it is flush with the front of the case 5 Turn the option card knobs to the locked positi...

Страница 3: ... has one RS422 485 port This port can be configured to act as either RS422 or RS485 The RS422 485 port and RS232 port are multiplexed because they share the same hardware Both ports can be used with master protocols However when the RS422 485 port is used with a slave protocol the RS232 port is not available Note All Red Lion devices connect A to A and B to B except for Paradigm devices Refer to w...

Страница 4: ...d based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warran...

Отзывы: