CONFIGURED USING CRIMSON SOFTWARE 

(VERSION 2.0 OR LATER)

O

ISOLATED RS232 AND RS485 MULTIPLEXED PORTS CAPABLE

OF COMMUNICATING WITH RS232, RS422, RS485 AND DH485
DEVICES AT UP TO 115,200 BAUD

O

EASY INSTALLATION

GENERAL DESCRIPTION

Both the Modular Controller Master (enhanced models) and Data Station

Plus contain a proprietary expansion port which provides a high speed, parallel
architecture that extends the functionality and flexibility of the platform. This
approach allows these products to evolve concurrently with the latest advances
in communications and standards, without sacrificing performance. This high
bandwidth channel has significantly greater throughput when compared to the
traditional (external) serial gateway approach.

The XCRS option card adds an additional RS232 and RS422/485 port to the

series. This isolated card protects user equipment from potentially harmful
ground loops while providing high-speed RS232, RS422, RS485, and DH485
communication options to the end user.

The XCRS communication card is easily installed by removing the blank

expansion port cover of your Modular Controller or Data Station Plus, and
plugging the XCRS card into the expansion port. Configuration is simple using
Red Lion's free Crimson 2.0 software.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.

CONTENTS OF PACKAGE

- XCRS option card
- This hardware bulletin

ORDERING INFORMATION

1

Contact your Red Lion distributor or visit www.redlion.net for complete

selection.

2

Red Lion offers RJ modular jack adapters. Refer to DR literature for

complete details.

3

Use these part numbers to purchase Crimson 2.0 on CD with a printed

manual, USB cable and RS-232 cable. Otherwise, download free of charge
from www.redlion.net.

SPECIFICATIONS

1. 

POWER REQUIREMENTS:

Power is supplied to the option card from the

main board of the Modular Controller Master or Data Station Plus.

2. 

COMMUNICATIONS:

Serial Ports

: Format and Baud Rates for each port are individually software

programmable up to 115,200 baud and are isolated to help prevent ground
loops. The RS422/485 and DH485 port via RJ45 and the RS232 port via
RJ12 share the same hardware. The XCRS option card multiplexes the ports
to communicate via two protocols. These ports may be used to configure
different master protocols, but only one port may be used if configuring a
slave protocol or AB DH485.

DH485 TXEN:

Transmit enable; open collector, V

OH

= 15 VDC, V

OL

= 0.5 VDC

Isolation from XCRS Communication ports to the Modular Controller
Master or Data Station Plus:

1000 VDC for 1 minute.

3. 

CERTIFICATIONS AND COMPLIANCES:

Refer to main unit manual or “Agency Approvals” section of Red Lion’s

website for agency certifications.

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,

Control and Laboratory use.

Reference Modular Controller Master or Data Station Plus unit for EMC

specifications

MODEL XCRS - RS232/485 OPTION CARD FOR DATA STATION PLUS AND 

MODULAR CONTROLLER

Bulletin No.  XCRS-X
Drawing No.  LP0669
Effective  5/07

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

MODEL NO.

DESCRIPTION

PART NUMBER

DR

CBL

XCRS

DRxxxxxx

CBLxxxxx

XCRS0000

SFCRM2

Crimson 2.0 with G3/Data Station Manual 

3

SFCRM200

SFCRM2

Crimson 2.0 with Modular Controller Manual 

3

SFCRM2MC

CAUTION: Risk of Danger.

Read complete instructions prior to 

installation and operation of the unit.

1

RS232/485 option card for Modular Controller
or Data Station Plus

Communication Cables 

1

DIN Rail Mountable Adapter Products 

2

Содержание XCRS

Страница 1: ...RMATION 1 Contact your Red Lion distributor or visit www redlion net for complete selection 2 Red Lion offers RJ modular jack adapters Refer to DR literature for complete details 3 Use these part numbers to purchase Crimson 2 0 on CD with a printed manual USB cable and RS 232 cable Otherwise download free of charge from www redlion net SPECIFICATIONS 1 POWER REQUIREMENTS Power is supplied to the o...

Страница 2: ...fy that the option card knobs are in the unlocked position as shown in Figure 2 4 Carefully insert the option card into the expansion port opening while aligning the card edge connector on the option card with the main board s header as shown in Figure 3 Once aligned gently press on the front of the card until it is flush with the front of the case 5 Turn the option card knobs to the locked positi...

Страница 3: ... has one RS422 485 port This port can be configured to act as either RS422 or RS485 The RS422 485 port and RS232 port are multiplexed because they share the same hardware Both ports can be used with master protocols However when the RS422 485 port is used with a slave protocol the RS232 port is not available Note All Red Lion devices connect A to A and B to B except for Paradigm devices Refer to w...

Страница 4: ...d based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warran...

Отзывы: