LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to one year from the

date of shipment, provided the products have been stored, handled, installed, and used under proper conditions.  The Company’s liability

under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option.  The Company

disclaims all liability for any affirmation, promise or representation with respect to the products.

The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising

out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths,

property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including

without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to

the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.

No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein.  The

Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.

APPLICATION

Cost efficiency measurements of a printing company included the

reduction of bulk stock of the various inks used in their printing processes.
The company currently had various ink flow and level devices with different
current and voltage outputs and wanted to record these measurements into a
control room PC. Several IAMA Universal Signal Conditioning Modules
were the answer. The IAMA’s universal input allowed for easy signal
conditioning of the various output signals to the required PC’s Bus Board 0
to 10 VDC input signal. The factory calibration settings of the IAMA could
be used with the devices in which the flow and level pressure was linear to
the signal. The IAMA could also be scaled utilizing the field calibration
method with the devices where pressure affected the signal slope
specifications. In this case, the IAMA’s re-transmitted 0 to 10 VDC output
was field calibrated, negating the expense and time required to rewrite the
PC’s software parameters. In addition to accepting multiple signal types and
field calibration features, the IAMA also provides the necessary electrical
isolation between the control room PC and the hazards of the printing floor
electrical noise.

Red Lion Controls 
20 Willow Springs Circle
York PA 17402
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls Asia

31, Kaki Bukit Road 3 #06-02 TechLink

Singapore 417818

Tel +65 6744-6613

Fax +65 6743-3360 

Red Lion Controls BV

Basicweg 11b

NL - 3821 BR Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Содержание IAMA Series

Страница 1: ...the field if desired The modules environmental operating temperature range is 20 C to 65 C DIN rail mounting saves time and panel space The units are equipped with universal mounting feet for attachment to standard DIN style rails including top hat profile rail according to EN50022 35x7 5 and 35 x 15 and G profile rail according to EN50035 G32 SAFETY SUMMARY All safety related regulations local co...

Страница 2: ...which restores the respective setting The Factory and Field E2PROM locations contain the same calibration values when the IAMA is received from the factory Therefore until the IAMA is field scaled factory and field modes perform identically See SCALING PROCEDURE for detailed instructions on field programming the IAMA The units can be scaled to any minimum scale and full scale values within the ext...

Страница 3: ...ive earth b Connect the shield to earth ground at both ends of the cable usually when the noise source frequency is above 1 MHz c Connect the shield to common of the unit and leave the other end of the shield unconnected and insulated from earth ground 2 Never run Signal or Control cables in the same conduit or raceway with AC power lines conductors feeding motors solenoids SCR controls and heater...

Страница 4: ...t 100 VDC Terminal 10 max signal input 100 mA Terminal 12 signal common 1 3 Set Input Range switches S1 switches 6 through 10 to the desired Input Range See Table 3 0 to 10 VDC range shown 1 4 Set Input Field Fact switch S1 switch 2 to the off position 1 5 Apply power to the IAMA Solid illumination of Green LED if signal is within the minimum and maximum limits of the selected input range Slow bli...

Страница 5: ...the Red LED blinks slowly and the Green LED turns off Removing power aborts scaling begin at Step 2 1 2 9 Apply maximum scale input The Red and Green LEDs will alternately blink 2 10 Set Input Field Fact switch S1 switch 2 to the on position Red LED extinguishes and Green LED becomes solid Your scaled values are now saved and recalled if the Input Field Fact switch S1 switch 2 is in the on positio...

Страница 6: ...max signal input 10 VDC Terminal 9 max signal input 100 VDC Terminal 10 max signal input 100 mA Terminal 12 signal common 4 9 Apply power to the IAMA and allow a warm up period of five minutes 4 10 Set Output Field Fact switch S1 switch 1 to the on position The Red and Green LEDs will alternately blink If Red LED blinks slowly increase signal until Red and Green LEDs alternately blink 4 11 Adjust ...

Страница 7: ... calibration is to be completed return S1 1 and S1 2 to the down position and remove power from the IAMA Apply power and check for accurate operation of the newly calibrated range or ranges OUTPUT RECALIBRATION 1 Complete 1 through 5 of the input recalibration procedure for at least one range 2 For current output set 20 mA 1 mA switch S2 to desired full scale output 20 mA on 1 mA off 3 Set Output ...

Страница 8: ...elies on no other warranties or affirmations APPLICATION Cost efficiency measurements of a printing company included the reduction of bulk stock of the various inks used in their printing processes The company currently had various ink flow and level devices with different current and voltage outputs and wanted to record these measurements into a control room PC Several IAMA Universal Signal Condi...