RS232 PORTS

The G308 has two RS232 ports. There is the PGM port and the COMMS port.

Although only one of these ports can be used for programming, both ports can
be used for communications with a PLC.

The RS232 ports can be used for either master or slave protocols with any

G308 configuration. 

Examples of RS232 communications could involve another Red Lion product

or a PC. By using a cable with RJ12 ends on it, and a twist in the cable, RS232
communications with another G3 product or the Modular Controller can be
established. Red Lion part numbers for cables with a twist in them are
CBLPROG0 

1

, CBLRLC01 

2

, or CBLRC02 

3

.

G3 RS232 to a PC

G308 PORT PIN OUTS

Connections

G3: RJ12

Name

PC: DB9

Name

4

COMM

1

DCD

5

Tx

2

Rx

2

Rx

3

Tx

N/C

4

DTR

3

COM

5

GND

N/C

6

DSR

1

CTS

7

RTS

6

RTS

8

CTS

N/C

9

RI

1

CBLPROG0 can also be used to communicate with either a PC or an ICM5.

2

DB9 adapter not included, 1 foot long.

3

DB9 adapter not included, 10 feet long.

ETHERNET COMMUNICATIONS

Ethernet communications can be established at either 10 BASE-T or 100

BASE-TX. The G308 unit’s RJ45 jack is wired as a NIC (Network Interface
Card). For example, when wiring to a hub or switch use a straight-through
cable, but when connecting to another NIC use a crossover cable.

The Ethernet connector contains two LEDs. A yellow LED in the upper right,

and a bi-color green/amber LED in the upper left. The LEDs represent the
following statuses:

The Crimson manual contains additional information on Ethernet

communications.

LED COLOR

DESCRIPTION

YELLOW solid

Link established

YELLOW flashing Data being transferred
GREEN

10 BASE-T Communications

AMBER

100 BASE-TX Communications

Содержание G308A

Страница 1: ...e details 4 Battery type is lithium coin type CR2025 5 Industrial grade two million write cycles MODEL G308A GRAPHIC LCD OPERATOR INTERFACE TERMINAL WITH VGA DISPLAY AND TOUCHSCREEN Bulletin No G308A E Drawing No LP0613 Released 1 08 Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net CompactFlash is a registered trademark of CompactFlash Association z CONFIGURED USING CRIMSON SOFTWARE VERSION 2...

Страница 2: ...omponent Recognition Program of Underwriters Laboratories Inc Type 4X Enclosure rating Face only UL50 UL Listed File E211967 UL61010 1 UL1604 CSA 22 2 No 61010 1 CSA 22 2 No 213 M1987 LISTED by Und Lab Inc to U S and Canadian safety standards IECEE CB Scheme Test Certificate US 9737C UL CB Scheme Test Report E179259 V01 S04 Issued by Underwriters Laboratories Inc IEC 61010 1 EN 61010 1 Safety requ...

Страница 3: ... low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred CONFIGURING A G308 The G308 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be pur...

Страница 4: ...Rx 3 Tx N C 4 DTR 3 COM 5 GND N C 6 DSR 1 CTS 7 RTS 6 RTS 8 CTS N C 9 RI 1 CBLPROG0 can also be used to communicate with either a PC or an ICM5 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G308 unit s RJ45 jack is wired as a NIC Network Interface Card For exam...

Страница 5: ...ler CBLRLC05 TxA 8 TxA 8 TxB 7 TxB 7 COM 6 COM 6 TxEN 5 TxEN 5 RxA TxA 3 2 2 3 RxA TxA 3 2 2 3 RxB 4 1 RxB 4 1 TxB 1 4 TxB 1 4 Name Modular Controller Name G3 Connections DH485 COMMUNICATIONS The G308 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are...

Страница 6: ...lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 User Manual TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscr...

Страница 7: ...our local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G308 is a lithium type CR2025 CAUTION RISK OF ELECTRIC SHOCK The inverter board attached to the mounting plate supplies the high voltage to operate the backlight Touching the inverter board may result in inj...

Страница 8: ... II cards Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with the G308 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending Information stored on a CompactFlash card by a G308 can be read by a card reader attached to a PC This information is stored ...

Отзывы: