background image

7

BATTERY & TIME KEEPING

A battery is used to keep time when the unit is without power. Typical

accuracy of the G306A time keeping is less than one minute per month drift. The
battery of a G306A unit does not affect the unit’s memory, all configurations and
data is stored in non-volatile memory.

To change the battery of a G306A, remove power, cabling, and then the rear

cover of the unit. To remove the cover, remove the four screws designated by
the arrows on the rear of the unit. Then, by lifting the top side, hinge the cover,
thus providing clearance for the connectors on the bottom side of the PCB as
shown in the illustration below. Install in the reverse manner.

Remove the old battery* from the holder and replace with the new battery.

Replace the rear cover, cables, and re-apply power. Using Crimson or the
unit’s keypad, enter the correct time and date.

* Please note that the old battery must be disposed of in a manner that

complies with your local waste regulations. Also, the battery must not be
disposed of in fire, or in a manner whereby it may be damaged and its
contents come into contact with human skin.

The battery used by the G306A is a lithium type CR2025.

CAUTION: RISK OF ELECTRIC SHOCK

The inverter board, attached to the mounting plate, supplies
the high voltage to operate the backlight. Touching the
inverter board may result in injury to personnel.

CAUTION

: The circuit board contains static sensitive

components. Before handling the operator interface without
the rear cover attached, discharge static charges from your
body by touching a grounded bare metal object. Ideally,
handle the operator interface at a static controlled clean
workstation. Also, do not touch the surface areas of the
circuit board. Dirt, oil, or other contaminants may adversely
affect circuit operation.

WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.

WARNING - EXPLOSION HAZARD - THE AREA MUST BE
KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/
REPLACING THE UNIT AND BEFORE INSTALLING OR
REMOVING I/O WIRING AND BATTERY.

Содержание G306A

Страница 1: ...ww redlion net 3 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 4 Battery type is lithium coin type CR2025 5 Industrial grade two million write cycles 6 The G...

Страница 2: ...net network to G3 operator interface 1500 Vrms 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum relative...

Страница 3: ...ates to Crimson for new features and drivers are posted on the website as they become available By configuring the G306A using the latest version of Crimson you are assured that your unit has the most...

Страница 4: ...PC By using a cable with RJ12 ends on it and a twist in the cable RS232 communications with another G3 product or the Modular Controller can be established Red Lion part numbers for cables with a twis...

Страница 5: ...er CBLRLC05 TxA 8 TxA 8 TxB 7 TxB 7 COM 6 COM 6 TxEN 5 TxEN 5 RxA TxA 3 2 2 3 RxA TxA 3 2 2 3 RxB 4 1 RxB 4 1 TxB 1 4 TxB 1 4 Name Modular Controller Name G3 Connections DH485 COMMUNICATIONS The G306A...

Страница 6: ...ck the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 User Manual TOUCHS...

Страница 7: ...our local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G306A i...

Страница 8: ...conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for an...

Отзывы: